EasyManuals Logo
Home>Nice>Engine>SPIN Series

Nice SPIN Series User Manual

Nice SPIN Series
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
GB
19
GB
7.2.5) Level one programming example (ON-OFF functions)
The sequence to follow in order to change the factory settings of the functions for activating “Automatic Closing” (L1) and “Motor force” (L3)
have been included as examples
1. Press the key [Set] and hold it down (approx. 3 s)
3s
2. Release the [Set] key when L1 LED starts flashing
L1
3. Press the [Set] key once to change the state of the function associated with
L1 (Automatic Closing). LED L1 will now flash with long flashes. L1
4. Press the [t] key twice to move the flashing LED to LED L3.
L3
5. Press the [Set] key once to change the state of the function associated with
L3 (Motor Force). LED L3 will now flash with long flashes.
6. Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Once these operations have been completed, LEDs L1 and L3 must remain on to indicate that the “Automatic Closing” and “Motor Force”
functions are active.
Table 19: Level one programming example Example
SET
SET
SET
SET
7.2.6) Level two programming example (adjustable parameters)
The sequence to follow in order to change the factory settings of the parameters increasing the “Pause Time” to 80s (input on L1 and level
on L4) and select the Open Door Indicator for the ”FLASH” output (input on L4 and level on L1) have been included as examples.
1. Press the key [Set] and hold it down (approx. 3 s)
3s
2. Release the [Set] key when L1 LED starts flashing
L1
3. Press the key [Set] and hold it down during step 4 and 5
4. Wait approx. 3 seconds until LED L2, which represents the currentlevel of the “Pause time”,
switches on. L2 3s
5. Press the [t]key twice to move the LED which is lit on to L4, which represents the new
“Pause Time” value. L4
6. Release the key [Set]
7. Press the [t] key 3 times to move the LED which is flashing to L4
L4
8. Press the key [Set]; and hold it down during step 9 and 10
9. Wait approx. 3s until LED L2, which represents the current device associated with the
”FLASH Output”, i.e. the flashing light. L2 3s
10. Press the [s] key one time to move the LED which is on to L1 which represents the new
device associated with the ”FLASH Output”, i.e. the “Open Door Indicator”. L1
11. Release the key [Set]
12. AWait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Table N°20: Level two programming example Example
SET
SET
SET
SET
SET
SET
7.3) Adding or Removing Devices
Devices can be added to or removed from the SPIN automation sys-
tem at any time. In particular, various devices types can be connect-
ed to “BLUEBUS” and “STOP” input as explained in paragraphs
“7.3.1 BlueBUS” and “7.3.2 STOP Input“.
7.3.1) BlueBUS
BlueBUS technology allows you to connect compatible devices
using only two wires which carry both the power supply and the
communication signals. All the devices are connected in parallel on
the 2 wires of the BlueBUS itself. It is not necessary to observe any
polarity; each device is individually recognized because a univocal
address is assigned to it during the installation. Photocells, safety
devices, control keys, signalling lights etc. can be connected to
BlueBUS The SPIN control unit recognizes all the connected devices
individually through a suitable recognition process, and can
detect all the possible abnormalities with absolute precision For this
reason, each time a device connected to BlueBUS is added or
removed the control unit must go through the recognition process;
see paragraph 7.3.4 “Recognition of Other Devices”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice SPIN Series and is the answer not in the manual?

Nice SPIN Series Specifications

General IconGeneral
BrandNice
ModelSPIN Series
CategoryEngine
LanguageEnglish

Related product manuals