Emergency Power Supply --- With PS124 accessory With PS124 accessory
FLASH Output
If programmed as “SPA “Open door indicator””: output for a maximum 24V-5W lamp;
if programmed as “Flashing light”: output for 1 LUCYB Flashing light (12V, 21W); if pro-
grammed as “Electric lock”: output for maximum 24V- 10W electro-mechanical lock;
if programmed as “Suction cup” output for maximum 24V- 10W electro-mechanical suc-
tion cup
Courtesy light SPIN
Courtesy light SPIN /V1
12V-21W socket BA15 230V-60W socket E27 230V-60W socket E27
12V-21W socket BA15 120V-60W socket E27 120V-60W socket E27
Use in acid, saline or potentially explosive
atmosphere
311x327 h 105 / 3,6Kg 311x327 h 105 / 4,7Kg
Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In
any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
All the technical characteristics refer to a room temperature of 20°C (±5°C)
8) Technical characteristics
Type
Technical characteristics: SPIN
Electromechanical gearmotor for the automatic movement of garage doors for residential
use, complete with electronic control unit
Pinion
Diameter 9.5mm, 28 teeth; for guides SNA5, SNA6 and guides supplied with SPIN20KCE,
SPIN30 and SPIN40
Model SN6021 SN6031 SN6041
Peak thrust
[corresponds to the force necessary to start
a leaf]
11.7Nm 11.7Nm 18Nm
[650N] [650N] [1000N]
5.85Nm 5.85Nm 9Nm
[345N] [345N] [560N]
Nominal torque
[corresponds to the force necessary to keep
a leaf moving]
Speed under no load [corresponding to if
“High speed” is programmed]
106 rpm
[0,20m/s]
The control unit enables programming of 4 speeds equal to approx. 100%-85%-70%-55%
Nominal torque speed [corresponds to if
“High speed” is programmed]
53 rpm
[0,08m/s]
Maximum frequency of operating cycles 50 cycles per day (the control unit allows up to the maximum described in tables 4 and 5)
Maximum continuous operating time
3 minutes (the control unit limits the continuous operation up to the maximum described in
tables 4 and 5)
Operating limits
Normally SPIN can automate sectional or overhead doors which remain within the dimen-
sions stated in table 3 and limits specified in tables 4 and 5.
Max. absorbed power 250W 250W 370W
266
Reduced consumption in Stand-By --- less than 2.2W less than 2.5W
Insulation class 1 (a safety grounding system is required)
Maximum BLUEBUS output load
STOP Input
For normally open contacts, for 8.2Kohm constant resistance, or normally closed contacts;
with self-recognition (any variation from the memorized status causes the “STOP” com-
mand
Step-by-step Input
For normally open contacts (the closing of the contact causes the “STEP-BY-STEP” command)
Radio AERIAL Input 52 ohm for RG58 or similar type of cable
Radio receiver “SM” connector for SMXI and SMXIS receivers
SPIN Power supply
SPIN/V1 Power supply
230Vac (±10%) 50/60Hz.
120Vac (±10%) 50/60Hz.
Programmable functions 4 ON-OFF functions and 4 adjustable functions (see tables 15 and 17)
Operating temperature -20°C ÷ 50°C
No
Protection class IP40 (use only in indoor or protected environments)
Dimensions / weight
Recognition functions
Recognition of the devices connected up to the BlueBUS output. Recognition of the type
of "STOP" device (Normally Open or Normally Closed contact or 8.2KΩ resistance).
Recognition of the door opening and closing positions and calculation of the slowdown
and partial opening points.