AFP-2800/2802 Manual – P/N 11249 11-Mar-08 153
8
8
.
.
1
1
6
6
.
.
2
2
C
C
O
O
N
N
N
N
E
E
C
C
T
T
I
I
O
O
N
N
T
T
O
O
I
I
F
F
S
S
-
-
7
7
2
2
4
4
T
T
E
E
R
R
M
M
I
I
N
N
A
A
T
T
I
I
O
O
N
N
B
B
O
O
A
A
R
R
D
D
1 2 3 4
A
B
C
D
4321
D
C
B
A
Rev
Size
Drg.
No.
Title
Sheet:
Date/
Drawn
Engineer
Design
Approved
This Drawing must not be used for Construction
unless signed as approved
7ColumbiaCourt,
NorwestBusinessPark
BaulkhamHillsNSW2153
AUSTRALIA
Tel
Fax
Email: support@inertia.com.au
A4
No.
Revision- revise onCAD. Donot amendby hand Eng. App. Date
Copyright
This document is & shall
remain theproperty of
Notifier Inertia Fire Systems
Unauthorised use of this
document in any wayis
prohibited.
DrawingFileNo.
C
O
61298941444
61298994156
G:\CONTRO~2\11915-NP.SCH
Of:
TOIFS724
TO / FROM IFS724
RL1
RL2
COM
N/O
N/C
COM
N/O
N/C
+24
0V
0V
+24
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
RL1
0V
+24
RL2
0V
+24
+24
0V
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
PCB1119
2A
DISTRIBUTION
BOARD
1A
AFP2800
TERMINATION BOARD
IFS724
FROM
TO
RELAY
!CA
!CF
!CI
!CL
ALARM
FAULT
ISOLATE
CHGLOW
(NORMALLY ENERGISED)
(FAILSAFE)
(SUGGESTED)
(PROGRAMMING)
EOL 4K7
W/SYS
-
+
BELL
+
-
FAULT
EVAC CONTROL
ALARM
STROBE CONNECTION
1.5R
5W
XR1
XR2
XR3
XR4
XR5
XR6
XR7
XR8
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
PCB717 RELAY EXPANSION
IN
OUT
J1
0.75mm
PSI SUPPLY
+240V
J4
TOPSI
FIT LINK ATJ6
ASE
CHG LOW (0V)
ALARM (NC)
FAULT (NC)
ISOLATE (N/C)
POWER
RED
BLACK
PROPOSED WIRING
CENTAUR ASE
N/C
COM
N/O
COM
N/O
COM
N/O
COM
ORANGE
PINK
YELLOW
BROWN
BLUE
PURPLE
WHITE
BLACK
12CORECABLE
#11396
+24
0V
10WEVAC POWER
1 1
27/4/07
G.W.
A
11915-NP
NPS POWER
ALSO FOR #11916, 17 &18
FOR 2800 FIP
NI-2012
CHGR BATT MAINS
FAULT FAULT FAIL
TST
PANEL BATTERY
BAT
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
0V
0V
0V
0V
+24
+24
+24
+24
N
N
N
J2
SUPPLY
+240V
PANEL
J5
0V
0V
+24
+24
PSI
1 2 3 4
ON
PANEL PANEL
AFP2800
ONLY NOT USED
DISPLAY
SW1
RESET/
BATT/TST
1 2 3 4
0 0 0 0
1 0 0 0
0 1 0 0
AUS2800
NZ2800
DGP
J3J4
TSTINH
BATTST
CHGFAIL
BATFAIL
MAINS
HEART BEAT
ONLYUSEDON AFP2800PCB 724
AFP2800
LN
V-
PBC-150 5.6A PSU
V+
+24
0V
CAB CONTROL J2-J4 POWER J5-J5
BASE #11871 #11877
18U #11872 #11869
28U #11873 #11875
40U #11974 #11874
J5
OPTION
NOTE
SP-320 (11A) REQUIRES3x0.47uF
ACROSS+V, -V, AND EARTH
+24
0V
1.5 mm
BATTERY
J2
1.5 MM
POWER IN
LN
V-
SP-320 11A PSU
V+
0.47uF
0.47uF0.47uF
24V
0V

Table of Contents

Other manuals for Notifier AFP-2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier AFP-2800 and is the answer not in the manual?

Notifier AFP-2800 Specifications

General IconGeneral
BrandNotifier
ModelAFP-2800
CategoryControl Panel
LanguageEnglish

Related product manuals