Connecting to the CX-Programmer Version 2.1 or Lower Section 3-8
71
5. Change the settings of [Network] and [Node] for [FINS Destination Ad-
dress] to the network address and the node address for the FINS address
displayed in the Guide to Connect.
· The routing table for FinsGateway must be changed if the Network ad-
dress is to be changed.
1. Do not change the unit address for the FinsGateway Communications Unit
with FinsGateway setting tool, etc. Changing the unit address may cause
the [Connect] operation to fail.
2. Do not set items to the local network table when setting the routing table
to the CX-Simulator. The local network table will automatically be changed
when [Connect] is executed. If communications with the Ladder Engine
can not be executed after setting the routing table, [Disconnect] and then
[Connect] again.
Note
3. If a new FinsGateway Communications Unit with the same name is
started by the FinsGateway service manager, etc. during [Connect], the
new unit will fail to start. The Communications Unit with the same name
can not be used simultaneously.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals