6-2 Initializing Data
6-11
1. Press the Data Log Button.
A confirmation message will be displayed. Press the Yes Button to initialize the data. Press the
No Button to cancel the initialize function.
2. When the PT has completed initializing the data log, a dialog box will be displayed indicating that
the data log has finished being initialized.
6-2-4 Operation Log Initialization
This function initializes the operation log saved in the PT.
Up to 1,024 operations can be recorded in order of occurrence.
Use this function when screen data has been changed, or for initializing log data.
The operation log is used to record number of times the following operations are performed
and the order in which they occur.
• Functional object operation history
• Screen display history
• Macro execution history
Refer to 2-4 System Memory in the PT Programming Manual for details.
Reference
• The functional objects that can be recorded are ON/OFF buttons, word buttons, Nu-
meral Display & Input, String Display & Input, and thumbwheel switches.
• The operation log data can also be initialized by setting the system bit memory ad-
dress $SB37 to ON from the host. Refer to 2-4 System Memory in the PT Program-
ming Manual for details.
• The operation log will be deleted when project data or system programs are down-
loaded.