44
3-9-4 Hood Assembly
Assemble the hood as shown in the following diagram.
ÇÇ
ÇÇ
Aluminum foil tape
Hood (FG) connected
to shield
Hood (FG) not connected to
shield
Boot
3-9-5 Recommended Cables and Connectors
Recommended Cable The following cables are recommended for connecting the host computer and
the Host Link Unit. Other cables can be used if desired as long as they meet the
required specifications.
Manufactured by Fujikura: UL2464 AWG28 x 5P IFS-RVV-SB (UL approved)
Manufactured by Hitachi: UL2464-SB 5P x AWG28 (UL approved)
Connector The following 9-pin connector, 25-pin connector, and connector hoods are pro-
vided with the Host Link Unit. The 9-pin connector is used at communications
ports 2 and 25-pin connector is used at communications port 1.
Item 9-pin connector 25-pin connector
Connector XM2A-0901 XM2A-2501
Connector hood XM2S-0911 XM2S-2511
3-9-6 Link Adapters
The following tables gives the specifications for Link Adapters suitable for use In Host Link Systems. Refer to
the C-series Link Adapters Installation Guide for details.
Link Adapter/
Application
Connection Supply voltage Operating
voltage range
Power
consumption
Weight
3G2A9-AL001
Branches RS-422
lines.
RS-422
RS-422RS-422
Not required –––
––– 250 g
max.
3G2A9-AL002-PE
Branches APF/PCF
lines.
Optical Fiber (APF/PCF)
Optical Fiber
(APF/PCF)
Optical Fiber
(APF/PCF)
100 to 120/
200 to 240 VAC
or 12 to 24 VAC/
DC
85 to 132/
170 to 246 VAC or
10.2 to 26.4 VAC/
DC
10 VA max. 900 g
max.
3G2A9-AL002-E
Branches PCF
lines.
Optical Fiber (PCF)
Optical Fiber
(PCF)
Optical Fiber
(PCF)
3G2A9-AL004-PE
Converters APF/
PCF, RS-422, and
RS-232C lines.
Optical Fiber
(APF/PCF)
RS-232C
RS-422
100 to 120/
200 to 240 VAC
85 to 110 VAC
170 to 220 VAC
10 VA max. 1 kg max.
3G2A9-AL004-E
Converters PCF,
RS-422, and
RS-232C lines.
Optical Fiber
(PCF)
RS-232C
RS-422
APF: all-plastic optical fiber cable; PCF: plastic-clad optical fiber cable
Wiring Section 3-9

Table of Contents

Other manuals for Omron SYSMAC CV1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CV1000 and is the answer not in the manual?

Omron SYSMAC CV1000 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CV1000
CategoryController
LanguageEnglish

Related product manuals