80
Response Format
@ WJ
Unit no. FCS TerminatorHeader
code
Response
code
*s
x 10
0
x 10
1
x 16
1
x 16
0
Parameters Beginning word (command): Specify in BCD the address of the first word to be
written to in the Auxiliary Area (0000 through 0255).
Data (command): Specify the data to be written in hexadecimal.
5-16 SV READ 1
Finds the specified timer or counter instruction in the program (main program
area) and reads the constant SV in 4-digit BCD. The SV of the timer/counter
must be a constant.
Note 1. Only the first instruction in the program that meets the specifications will be
found.
2. Up to 10 seconds can be required to receive a response because the pro-
gram is searched from the beginning.
3. If the SV is not defined using a constant, a response code of 16 will be re-
turned indicating that the specified instruction does not exist.
4. Only the main program will be searched for CVM1 PCs.
5. If the PC is programmed using SFC, only action 0 will be searched. The en-
tire main program will be searched if SFC programming is not used.
Command Format
@ R#
FCS
x 10
0
x 10
1
OP2 OP4OP3 x 10
2
x 10
3
x 10
0
x 10
1
OP1
Unit no. TerminatorHeader code Timer/Counter instruction Timer/Counter number
*s
Response Format
@ R#
x 10
0
x 10
1
x 16
0
x 16
1
x 10
2
x 10
3
x 10
0
x 10
1
Unit no. FCS TerminatorHeader
code
Response
code
SV
*s
SV READ 1 Section 5-16

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CV1000 and is the answer not in the manual?

Omron SYSMAC CV1000 Specifications

General IconGeneral
ManufacturerOmron
TypePLC
Memory CapacityNot specified in detail
Communication PortsRS-232C
Power Supply24 VDC or 100-240 VAC (depending on model)
Operating Temperature0°C to 55°C
Humidity10% to 90% (non-condensing)
Vibration Resistance10 to 57 Hz, 0.075 mm amplitude
Shock Resistance10 G
ModelSYSMAC CV1000

Summary

SECTION 1 Introduction

SECTION 2 Switch Settings and Communications Parameters

2-2 Host Link Unit Settings and Parameters

Details on Host Link Unit components, switches, and setting procedures.

SECTION 3 Installation

3-4 RS-232C Connections

Specifications and connection methods for RS-232C connections.

3-5 RS-422 Connections

Specifications and connection methods for RS-422 connections.

SECTION 4 Communications

4-1 Initial Communications Test

Steps for performing an initial test to verify system operability.

4-3 C-mode Commands

Details C-mode commands, protocol, blocks, and checksum calculation.

4-5 Communications Timing

Explains transmission timing in full-duplex and half-duplex communications.

SECTION 5 C-mode Commands

5-24 ERROR READ

Reads and clears PC errors.

SECTION 6 Maintenance and Troubleshooting

6-1 Maintenance

Explains maintenance methods and procedures for the Host Link System.

Appendix D Sample Programs Including Commands for Host Computer

Related product manuals