89
Operand (command): Specifies whether to use a constant or word to change
the SV of the timer/counter and, if a word is used, specifies the data area of the
word (see below).
New SV (command): Specifies the constant or address to change the SV to in
BCD.
Operand
Constant/Area New SV
OP1 OP2 OP3 OP4
(see note)
C O N space Constant 0000 to 9999
C I O space CIO Area 0000 to 2555
G R space space CPU Bus Link Area 0000 to 0255
A R space space Auxiliary Area 0000 to 0511
T I M space Timer Area
0000 to 0511 or
D M
*
space Indirect DM address
00000 to 09999
E M space space EM Area
00000 to 09999
E M
*
space Indirect EM address
D R space space Data Register 0000 to 0002
I R space space Index Register 0000 to 0002
, I R space Indirect index
register address
0000 to 0002 (offsets and
other details cannot be
read)
Note 1. A total of four letters are required to specify the operand. Be sure to include
spaces where necessary.
2. Word address ranges depend on the CPU being used. Refer to the CV-se-
ries Operation Manual: Ladder Diagrams for details.
5-22 STATUS READ
Reads the operating status of the PC.
Command Format
@ MS
Unit no. FCS TerminatorHeader
code
*s
x 10
0
x 10
1
Response Format
@ MS
Unit no. Response
code
FCS TerminatorHeader
code
Status data Message
*s
x 10
0
x 10
1
x 16
1
x 16
0
x 16
3
x 16
2
x 16
1
x 16
0
16 characters
STATUS READ Section 5-22