Version 4.7/4.92/5.12
18 | Zone Timers
Magellan & Spectra SP • Programming Guide
Custom Zone Definitions
With MG/SP control panels you can create up to four custom zone definition templates (use worksheet 8). Custom zone definition templates (sections [033] to
[036]) will overwrite zone definitions 33 to 36 in table 5 on page 16. Modifications can be made in accordance with table 9 (Permitted zone definitions for MG/SP
panels), on page 17.
Zone Timers
Use the following section to program zone timers for your MG/SP control panel. Use worksheets 9 and 10 to record your settings.
NOTE: When both ATZ and EOL are enabled, the zone speed should not be set below 300 msec.
MG Series
SP Series
Worksheet 8: Custom Zone Definitions
Section Description Disarm Stay Arm Sleep Arm Full Arm
[033] Zone definition template 1 _____/_____ _____/_____ _____/_____ _____/_____
[034] Zone definition template 2 _____/_____ _____/_____ _____/_____ _____/_____
[035] Zone definition template 3 _____/_____ _____/_____ _____/_____ _____/_____
[036] Zone definition template 4 _____/_____ _____/_____ _____/_____ _____/_____
Worksheet 9: Zone Timers for the MG Series
Section Zone MG5000 MG5050 Data Description (default: 060)
[041] 1 (Z1) (Z1) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 1
[042] 2 (Z2) (Z2) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 2
[043] 3 (Z1 ATZ) (Z3) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 3
[044] 4 (Z2 ATZ) (Z4) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 4
[045] 5 (Z5) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 5
[046] 6 (Z1 ATZ) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 6
[047] 7 (Z2 ATZ) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 7
[048] 8 (Z3 ATZ) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 8
[049] 9 (Z4 ATZ) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 9
[050] 10 (Z5 ATZ) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 10
[051] 11 ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 11
[052] 12 ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 12
[053] 13 ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 13
[054] 14 ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 14
[055] 15 ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 15
[056] 16 ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 16
Worksheet 10: Zone Timers for the SP Series
Section Zone SP4000 SP5500 SP6000 SP65* SP7000** Data Description (default: 060)
[041] 1 (Z1) (Z1) (Z1) (Z1) (Z1) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 1
[042] 2 (Z2) (Z2) (Z2) (Z2) (Z2) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 2
[043] 3 (Z3) (Z3) (Z3) (Z3) (Z3) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 3
[044] 4 (Z4) (Z4) (Z4) (Z4) (Z4) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 4
[045] 5 (Z1 ATZ) (Z5) (Z5) (Z5) (Z5) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 5
[046] 6 (Z2 ATZ) (Z1 ATZ) (Z6) (Z6) (Z6) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 6
[047] 7 (Z3 ATZ) (Z2 ATZ) (Z7) (Z7) (Z7) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 7
[048] 8 (Z4 ATZ) (Z3 ATZ) (Z8) (Z8) (Z8) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 8
[049] 9 (Z4 ATZ) (Z1 ATZ) (Z9) (Z9) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 9
[050] 10 (Z5 ATZ) (Z2 ATZ) (Z1 ATZ) (Z10) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 10
[051] 11 (Z3 ATZ) (Z2 ATZ) (Z11) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 11
[052] 12 (Z4 ATZ) (Z3 ATZ) (Z12) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 12
[053] 13 (Z5 ATZ) (Z4 ATZ) (Z13) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 13
[054] 14 (Z6 ATZ) (Z5 ATZ) (Z14) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 14
[055] 15 (Z7 ATZ) (Z6 ATZ) (Z15) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 15
[056] 16 (Z8 ATZ) (Z7 ATZ) (Z16) ____/____/____ (000 to 255) x 10 msec. Speed of hardwire zone 16
* For zones 17-18 (ATZ), the zone timer is set to 600 msec.
** For zones 17-32 (ATZ), the zone timer is set to 600 msec.