Magellan & Spectra SP Programming Guide • Description of Sections [700] to [704] Wireless Siren Labels | 37
Cancelling the Tamper Supervision for Wireless Sirens
To cancel tamper supervision, access section [695], and then press ENTER. The tamper supervision is disabled until the cover is replaced or after 30 minutes have elapsed.
Description of Sections [700] to [704]
The following section provides information on sections [700] to [704]. See table 25 for details. For keypad programming instructions, refer to on page 7.
Table 25: Description of sections [700] to [704]
Option Option Type Description OFF ON Option Option Type Description OFF ON
Section [700]
1 Partitioning Partitioning Disabled
Enabled
Section [701]
1
Access/master code
options
Access code length*
6 digits 4 digits
2
General system options
Battery charging, 350 mA or 700 mA
(not applicable to SP4000 and SP65)
350 mA
700 mA 2 Lock master code Disabled
Enabled
3
Audible trouble warning (except AC
failure)
Disabled
Enabled 3
Keypad options 1**
Confidential mode Disabled
Enabled
4 Audible trouble warning on AC failure Disabled
Enabled 4 To exit confidential mode Enter code
Press a key
5 RF jamming supervision RF jamming supervision
Disabled Enabled 5 Confidential mode timer 2 mins.
5 secs.
6
General system options
Exit delay termination Disabled
Enabled 6 REM2 version number REM2 version number
V2.00
V2.01 or
higher
7 Tamper supervision on the bus module Disabled
Enabled 7
Keypad options 1
Display entry delay on LCD keypad
Disabled Enabled
8Future use - ---- 8 Display exit delay on LCD keypad
Disabled Enabled
Section [702]
1
Panic options
Panic 1 Disabled
Enabled
Section [703]
1
Keypad options 2
One-touch regular arming (also REM3)
Disabled Enabled
2Panic 2 Disabled
Enabled 2 One-touch stay arming (also REM3)
Disabled Enabled
3Panic 3 Disabled
Enabled 3 One-touch sleep arming (also REM3)
Disabled Enabled
4 Panic 1: report only or audible alarm Report only
Audible 4 One-touch bypass programming
Disabled Enabled
5 Panic 2: report only or audible alarm Report only
Audible 5
Arming/disarming options
Restrict arming on battery failure Disabled
Enabled
6 Panic 3: report only or audible alarm Report only
Audible 6
Restrict arming on tamper failure (zone
+ bus module + wireless PGM)
Disabled
Enabled
7Future use - ---- 7
Restrict arming on supervision trouble;
wireless zones & PGM + bus module
Disabled
Enabled
8Future use - ---- 8Arm/disarm with VDMP3Arm/disarm with VDMP3
Disabled Enabled
Section [704]
1
Arming/disarming options
Regular arming switches to force
arming
Disabled Enabled
= Default
*All numbers from 000000 to 999999 are valid giving a total o f 1,000,000 different possible combinations.
**Automatic timed operation that will make indications inaccessible to users without a valid access code.
2
Stay arming switches to stay force
arming
Disabled Enabled
3
Sleep arming switches to sleep force
arming
Disabled Enabled
4
Bell squawk when arm/disarm with
remote
Disabled
Enabled
5
Keypad options 3
Bell squawk when arm/disarm with a
keypad
Disabled
Enabled
6 Beep on exit delay
Disabled Enabled
7
No exit delay beeps and no bell
squawk, when stay/sleep arm
Disabled Enabled
8 Arming/disarming options No exit delay when arm with remote Disabled
Enabled