EasyManuals Logo
Home>Paradox>Security System>Spectra SP7000

Paradox Spectra SP7000 User Manual

Paradox Spectra SP7000
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Magellan & Spectra SP • Programming Guide
Version 4.7/4.92/5.12
Appendix A | 69
General Zone Options
Miscellaneous System Options
System Timers
Table 62: Description of options 3 & 4 and 6 & 7, in section [705]
Option Description
3 4 RF Zone/Hardwired Zone Tamper Recognition Options Keypad/Bus Module Tamper Recognition Options*
OFF OFF Disabled Disabled
OFF ON Trouble only Trouble only
ON OFF When disarmed: trouble only; when armed: follow zone’s alarm type Trouble only
ON ON When disarmed: audible alarm; when armed: follow zone’s alarm type Audible alarm
6 7 RF Zone Supervision Options Keypad/Bus Module Supervision Options
OFF OFF Disabled Disabled
OFF ON Trouble only Trouble only
ON OFF When disarmed: trouble only; when armed: follow zone’s alarm type Trouble only
ON ON When disarmed: audible alarm; when armed: follow zone’s alarm type Audible alarm
* Tamper recognition of keypad/bus module, only if section [700], option 7, is enabled.
Table 63: Description of section [706]
Option Description OFF ON
Section [706]
1 Check-in supervision time
24 hours 80 minutes
2 EOL resistors (applies to all hardwired zones – panel, keypad, ZX8)
Disabled Enabled
3 Zone input 1 becomes a two-wire smoke input (except SP4000, SP5500, and SP65) Disabled
Enabled
4 ZX8 ID A (panel + 1) input 1
Zone input Tamper input
5 ZX8 ID B (panel + 9) input 1
Zone input Tamper input
6 ZX8 ID C (panel + 17) input 1
Zone input Tamper input
= Default
Table 64: Description of section [708]
Option Description OFF ON
Section [708]
EN50131
OPTIONS
1 Enter code to view trouble
One-touch Enter code
2 Enter code to view alarm in memory/event list
One-touch Enter code
3 Trouble latch
Disabled Enabled
4 Bell squawk on Installer in
Disabled Enabled
5 Acknowledge trouble(s) before arming
Disabled Enabled
6 Do not arm if zone opens during exit delay
Disabled Enabled
7 Disable ‘Bypass and Arm’
Disabled Enabled
8 Future use - - - -
= Default
Worksheet 56: System Timers
Section Data Description Section Data Description
[710] ___/___/___ 000 to 255 seconds Entry delay 1* (default: 045) [718] ___/___/___ 000 to 255 seconds
Remote panic disarm lock delay
(default: 000)
[711] ___/___/___ 000 to 255 seconds Entry delay 2* (default: 045) [719] ___/___/___ 000 to 255 days
Closing delinquency delay
(default: 000)
[712] ___/___/___ 000 to 015
Auto-zone shutdown counter
(default: 005) [720] ___/___/___ 000 to 255 seconds Flex-instant delay (default: 015)
[713] ___/___/___ 000 to 255 seconds Intellizone delay (default: 048) [721] ___/___/___ 000 to 255 seconds
For StayD: re-arm delay
(default: 005)
[714] ___/___/___ 000 to 255 minutes Recycle alarm delay (default: 000) [722] ___/___/___ 000 to 255 seconds
Auto trouble shutdown**
(default: 010)
[715] ___/___/___ 000 to 255
Recycle alarm counter
(default: 000) [723] ___/___/___ 000 to 255 seconds
Panic shutdown**
(default: 010)
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP7000 and is the answer not in the manual?

Paradox Spectra SP7000 Specifications

General IconGeneral
BrandParadox
ModelSpectra SP7000
CategorySecurity System
LanguageEnglish

Related product manuals