Magellan & Spectra SP • Programming Guide
Version 4.7/4.92/5.12
System and Communication Report Codes | 49
Automatic Report Codes
Table 45: List of automatic report codes
System Event Default Contact ID Report Code Default SIA Report Code
Arming with user code (##) 3 4A1 Close by user CL Closing report
Auto arming 3 4A3 Automatic close CA Automatic closing
Late to close 3 452 Late to close OT Late to close
No movement 3 452 Late to close NA No activity
Partial arming 1 456 Group bypass CG Close area
Quick arming 3 4A8 Quick arm CL Closing report
Arm with PC software 3 4A7 Remote arm/disarm CQ Remote arming
Keyswitch arming 3 4A9 Keyswitch arming CS Keyswitch arming
Disarm with user code (##) 1 4A1 Open by user OP Opening report
Disarm after alarm with user code (##) 1 4A1 Open by user OP Opening report
Cancel alarm with user code (##) 1 4A6 Cancel by user OR Disarm from alarm
Auto arming cancellation 1 464 Deferred open/close CE Closing extend
Disarm with PC software 1 4A7 Remote arm/disarm OQ Remote disarming
Disarm after an alarm with PC software 1 4A7 Remote arm/disarm OR Disarm from alarm
Cancel alarm with PC software 1 4A6 Cancel by user OR Disarm from alarm
Cancel paramedic alarm 1 4A6 Cancel by user MH Medical alarm restore
Keyswitch disarm 1 4A9 Keyswitch disarm OS Keyswitch disarm
Keyswitch disarm after alarm 1 4A1 Keyswitch disarm after alarm OS Keyswitch disarm after alarm
Keyswitch cancel alarm 1 4A6 Keyswitch cancel alarm OS Keyswitch cancel alarm
Zone bypassed (##) 1 57A Zone bypass UB Untyped zone bypass
Zone alarm (##) 1 13A Burglary alarm BA Burglary alarm
Fire alarm (##) 1 11A Fire alarm FA Fire alarm
Zone alarm restore (##) 3 13A Burglary alarm restore BH Burglary alarm restore
Fire alarm restore (##) 3 11A Fire alarm restore FH Fire alarm restore
24-hr gas alarm (##) 1 151 Gas detected GA Gas alarm
24-hr heat alarm (##) 1 153 Loss of heat KA Heat alarm
24-hr water alarm (##) 1 154 Water leakage WA Water alarm
24-hr freeze alarm (##) 1 152 Refrigeration ZA Freeze alarm
24-hr gas alarm restore (##) 3 151 Gas restore GR Gas alarm restore
24-hr heat alarm restore (##) 3 153 Heat restore KR Heat alarm restore
24-hr water alarm restore (##) 3 154 Water restore WR Water alarm restore
24-hr freeze alarm restore (##) 3 152 Freeze restore ZR Freeze alarm restore
24-hr hold-up alarm 1 12A Panic alarm PA Panic alarm
24-hr hold-up alarm restore 3 12A Panic alarm restore PR Panic restore
Panic 1: emergency 1 12A Panic alarm PA Panic alarm
Panic 2: medical 1 1AA Medical alarm MA Medical alarm
Panic 3: fire 1 115 Pull station FA Fire alarm
Recent closing 3 459 Open/close CR Recent closing
Global zone shutdown 1 575 Group bypass CG Close area
Duress alarm 1 121 Duress HA Hold-up alarm
Keypad lockout 1 421 Access denied JA User code tamper
Zone shutdown (##) 1 57A Zone bypass UB Untyped zone bypass
Zone tampered (##) 1 144 Sensor tamper TA Tamper alarm
Zone tamper restore (##) 3 144 Sensor tamper restore TR Tamper restoral
TLM Trouble 1 351 Telco 1 fault LT Phone line trouble
AC failure 1 3A1 AC loss AT AC trouble
Battery failure 1 3A9 Battery test failure YT System battery trouble
Auxiliary supply trouble 1 3AA System trouble YP Power supply trouble
Bell output current limit 1 321 Bell 1 YA Bell fault

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP7000 and is the answer not in the manual?

Paradox Spectra SP7000 Specifications

General IconGeneral
BrandParadox
ModelSpectra SP7000
CategorySecurity System
LanguageEnglish

Related product manuals