Version 4.7/4.92/5.12
42 | Communication Programming
Magellan & Spectra SP • Programming Guide
Communication Programming
Use the following section to program various communication features on your MG/SP control panel. Table 34 lists features available for each MG/SP control panel.
Prioritization of signals and messages are based on a “first in, first out” scheme. Systems meet EN 50136 ATS2 or ATS3 requirements when configured as depicted.
NOTE: For increased security, it is suggested that redundant communication methods be installed.
Dialer Options
Table 34: Communication features for MG/SP panels
Communication Feature
Control Panel
MG5000 MG5050 SP4000 SP5500 SP6000 SP65 SP7000
GPRS reporting (PCS series) 
GSM reporting and SMS (PCS series) 
IP reporting (IP100) 
E-mail/monitoring (IP100) 
Patented dialer  -
Supports VDMP3 
Table 35: Description of dialer options for landline communication (section [800])
Option Description OFF ON
Option
Description
Section [800]
1 & 2 Telephone line monitoring
See options 1
& 2, on right
See options 1
& 2, on right
3 Switch to pulse on fifth attempt Disabled
Enabled 1 2
4Alternate dial Disabled
Enabled OFF OFF Disabled (default)
5 Force dial (must be enabled to comply with TBR-21)
Disabled Enabled OFF ON Trouble only
6DTMF dialing
Disabled Enabled ON OFF
When disarmed: trouble only; when
armed: audible only
7 Pulse ratio
1:2 1:1.5 ON ON Silent alarms become audible alarm
8Reporting*
Dialer
activated
No dialer
= Default
* This option also applies to both landline and GSM communication (see Landline and GSM Communication on page 44).
Table 36: Description of general communication dialer options (section [801])
Option Description OFF ON
Section [801]
1 Report system disarming
Always After alarm
2Report zone restore Bell cutoff
Zone closure
3 & 4 Auto-test report transmission
See table 37 on page 42
See table 37 on page 42
5Contact ID override Disabled
CID defaults/slow format
custom
6 Bell squawk upon alarm report confirmation (SP4000 and SP65 only)
Disabled Enabled
7 Bell squawk upon arming report confirmation (SP4000 and SP65 only) Disabled
Enabled
8 Keypad beeps upon arming report confirmation (SP4000 and SP65 only)
Disabled Enabled
= Default
Table 37: Auto-test report transmission options (section [801])
Option
Description
3 4
1 OFF OFF
Transmit the test report code when the days programmed in section [840] have elapsed, at the time programmed in section
[850] (default).
2OFF ON
When disarmed: transmit test report code when the time programmed in section
[852] has elapsed. When armed: transmit test
report code when the time programmed in section [851] has elapsed.
3ON OFF
The control panel will transmit the test report code every hour, on the minute value programmed in section [850] (the last two
digits); the first two digits of section [850] will be ignored. For example, if 10:25 was programmed into section [850], the test
report code would be transmitted at the 25th minute of every hour, i.e., 11:25, 12:25, etc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP7000 and is the answer not in the manual?

Paradox Spectra SP7000 Specifications

General IconGeneral
BrandParadox
ModelSpectra SP7000
CategorySecurity System
LanguageEnglish

Related product manuals