Magellan & Spectra SP • Programming Guide
Version 4.7/4.92/5.12
System and Communication Report Codes | 47
Contact ID Report Codes
Table 44: Ademco contact ID report codes
Type CID # Reporting Code Value
Medical Alarms
(100)
100 Medical alarm 01
101 Pendant transmitter 02
102 Fail to report in 03
Fire Alarms
(110)
110 Fire Alarm 04
111 Smoke 05
112 Combustion 06
113 Water Flow 07
114 Heat 08
115 Pull Station 09
116 Duct 0A
117 Flame 0B
118 Near Alarm 0C
Panic Alarms
(120)
120 Panic alarm 0D
121 Duress 0E
122 Silent 0F
123 Audible 10
124 Duress - access granted 11
125 Duress - egress granted 12
Burglar Alarms
(130)
130 Burglary 13
131 Perimeter 14
132 Interior 15
133 24-hour 16
134 Entry/exit 17
135 Day/night 18
136 Outdoor 19
137 Tamper 1A
138 Near alarm 1B
139 Intrusion verifier 1C
General Alarms
(140)
140 General alarm 1D
141 Polling loop open 1E
142 Polling loop short 1F
143 Extension module failure 20
144 Sensor tamper 21
145 Expansion module tamper 22
146 Silent burglary 23
147 Sensor supervision failure 24
24-hour Non-burglary
(150 & 160)
150 24-hour non-burglary 25
151 Gas detected 26
152 Refrigeration 27
153 Loss of heat 28
154 Water leakage 29
155 Foil break 2A
156 Day trouble 2B
157 Low bottled gas level 2C
158 High temperature 2D
159 Low temperature 2E
161 Loss of air flow 2F
162 Carbon monoxide detected 30
163 Tank level 31
Fire Supervisory
(200 & 210)
200 Fire supervisory 32
201 Low water pressure 33
202 Low CO2 34
203 Gate valve sensor 35
204 Low water level 36
205 Pump activated 37
206 Pump failure 38
System Troubles
(300 & 310)
300 System trouble 39
301 AC loss 3A
302 Low system battery 3B
303 RAM checksum bad 3C
304 ROM checksum 3D
305 System reset 3E
306 Panel program changed 3F
307 Self-test failure 40
308 System shutdown 41
309 Battery test failure 42
310 Ground fault 43
311 Battery missing/dead 44
312 Powr. supply over current limit 45
313 Engineer reset 46
Sounder/Relay Troubles
(320)
320 Sounder relay 47
321 Bell 1 48
322 Bell 2 49
323 Alarm relay 4A
324 Trouble relay 4B
325 Reversing relay 4C
326 Notification appliance chk. #3 4D
327 Notification appliance chk. #4 4E
Table 44: Ademco contact ID report codes (Continued)
Type CID # Reporting Code Value
System Peripheral Troubles
(330 & 340)
330 System peripheral 4F
331 Polling loop open 50
332 Polling loop short 51
333 Expansion module failure 52
334 Repeater failure 53
335 Local printer paper out 54
336 Local printer failure 55
337 Exp. module DC loss 56
338 Exp. module low battery 57
339 Exp. module reset 58
341 Exp. module tamper 59
342 Exp. module AC loss 5A
343 Exp. module self-test fail 5B
344 RF receiver jam detected 5C
Communication Troubles
(350 & 360)
350 Communication 5D
351 Telco fault 1 5E
352 Telco fault 2 5F
353 Long range radio 60
354 Fail to communicate 61
355 Loss of radio supervision 62
356 Loss of central polling 63
357
Long range radio VSWR
problem
64
Protection Loop Troubles
(370)
370 Protection loop 65
371 Protection loop open 66
372 Protection loop short 67
373 Fire trouble 68
374 Exit error alarm 69
375 Panic zone trouble 6A
376 Hold-up zone trouble 6B
377 Swinger trouble 6C
378 Cross-zone trouble 6D
Sensor Troubles
(380 & 390)
380 Sensor trouble 6E
381 Loss of supervision - RF 6F
382 Loss of supervision - RPM 70
383 Sensor tamper 71
384 RF transmitter low battery 72
385 Smoke detector hi sensitivity 73
386 Smoke detector low sensitivity 74
387
Intrusion detector hi
sensitivity
75
388
Intrusion detector low
sensitivity
76
389 Sensor self-test failure 77
391 Sensor watch trouble 78
392 Drift compensation error 79
393 Maintenance alert 7A
Table 44: Ademco contact ID report codes (Continued)
Type CID # Reporting Code Value

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP7000 and is the answer not in the manual?

Paradox Spectra SP7000 Specifications

General IconGeneral
BrandParadox
ModelSpectra SP7000
CategorySecurity System
LanguageEnglish

Related product manuals