12
9850068 R01 - 2020-2021 RZR PRO XP / XP 4 Service Manual
© Copyright Polaris Industries Inc.
12.31
FAN CONTROL CIRCUIT BYPASS TEST
1. Disconnect harness from coolant temperature
sensor on the engine cylinder head (see Engine
Coolant Temperature Sensor (ECT) Overview
outlined in this chapter).
2. With the transmission in Park, start the engine. After
a few seconds, the fan should start running and the
“Check Engine” indicator should display on the
instrument cluster. This indicates all other
components are working properly.
3. If the fan does not run or runs slowly, check the fan
motor wiring, ground, motor condition, circuit breaker
and mechanical relay for proper operation. Repair or
replace as necessary. If the fan runs with the sensor
harness disconnected, but will not turn on when the
engine is hot, check the coolant temperature sensor
and connector terminals.
COOLING FAN REPLACEMENT
REMOVAL
1. Remove front fascia. See Front Fascia Removal page
11.17.
2. Drain cooling system.
3. Remove four electrical connectors from the voltage
regulators.
4. Remove two fasteners
q
securing voltage regulator
bracket and remove bracket/voltage regulators as an
assembly.
5. Remove six push pins
w
and remove the radiator
shroud.
6. Remove two large hoses and one vent line from the
charge air radiator and remove charge air radiator
from the vehicle.
ELECTRICAL