VOLTAGE REGULATOR
The regulator / rectifier is located between the front
fascia and the radiator.
NOTE
If the regulator / rectifier case temperature exceeds
230° F or 110° C, the unit will turn itself off to cool down.
The unit will turn on again after it has cooled down to at
least 212° F or 100° C. If it turns off, verify the cooling
fins are clean, free from mud/debris and that adequate
airflow is present.
REGULATOR REPLACEMENT
1. Disconnect the negative battery terminal.
2. Push the locking tabs down on the front fascia grill
and remove the grill.
3. Disconnect both regulator connectors
q
.
4. Remove the two regulator mounting fasteners
w
and
remove the regulator through the grill opening.
5. Install regulator onto the mounting plate. Torque
mounting fasteners to specification.
TORQUE
Regulator Mounting Fasteners:
5 ft-lb (7 Nm)
6. Connect the regulator harness connectors. The
connectors are keyed so each connector will only fit
on one of the regulator connectors.
7. Install the grill. Ensure the bottom tabs and the clips
are locked into the front fascia.
8. Install the battery negative terminal. Torque fastener
to specification.
TORQUE
Battery Terminal Fastener:
60 in-lbs (7 Nm)
ELECTRICAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris RZR XP4 1000 2017 and is the answer not in the manual?

Polaris RZR XP4 1000 2017 Specifications

General IconGeneral
BrandPolaris
ModelRZR XP4 1000 2017
CategoryAutomobile
LanguageEnglish

Related product manuals