9.2 Partition Options 2 (Function 401)
Press .
This starts the function
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current partition options are displayed.
Select any option by using the and
keys, or use the keys to select that
option directly.
Press to toggle the option
ON
or
OFF
.
Press to accept the options.
There are 6 options
SYSTEM OPTIONS 1
OPTION 6 ON
SYSTEM OPTIONS 1
OPTION 5 OFF
SYSTEM OPTIONS 1
OPTION 4 OFF
SYSTEM OPTIONS 1
OPTION 3 OFF
SYSTEM OPTIONS 1
OPTION 2 OFF
PARTITION OPT 2
OPTION 1 OFF
OPTION OFF OPTION ON
1 Bell Time in Minutes Bell Time in Seconds
2 Anti-Code Reset disabled Anti-Code Reset Enabled
*3 Engineer Reset Disabled Engineer Reset Enabled
*4 Reset required After Confirmed Alarms Reset Required After All Alarms
5 Normal Sounder Operation French Sounder Operation
6 Do Not Allow Zone Restorals After Reset Allow Zone Restorals After Reset
7
8
Reserved for Future Use. Do Not Alter.
Shaded = Default
*IMPORTANT NOTE ON ENGINEER RESET
Please note that if the below options are both turned ON; an Engineer Reset is only needed for any
TAMPER ALARMS.
A user code will be able to reset ALL OTHER ALARMS.
O
PTION
N
UMBER
3
=
E
NGINEER
R
ESET
E
NABLED
O
PTION
N
UMBER
4
=
R
ESET
R
EQUIRED
A
FTER
A
LL
A
LARMS

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals