Matrix 424/832/832+ LCD Programming Manual
RINS916-6 Page 27
9.2 Partition Options 2 (Function 401)
Press .
This starts the function
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current partition options are displayed.
Select any option by using the and
keys, or use the – keys to select that
option directly.
Press to toggle the option
ON
or
OFF
.
Press to accept the options.
There are 6 options
SYSTEM OPTIONS 1
OPTION 6 ON
SYSTEM OPTIONS 1
OPTION 5 OFF
SYSTEM OPTIONS 1
OPTION 4 OFF
SYSTEM OPTIONS 1
OPTION 3 OFF
SYSTEM OPTIONS 1
OPTION 2 OFF
PARTITION OPT 2
OPTION 1 OFF
№ OPTION OFF OPTION ON
1 Bell Time in Minutes Bell Time in Seconds
2 Anti-Code Reset disabled Anti-Code Reset Enabled
*3 Engineer Reset Disabled Engineer Reset Enabled
*4 Reset required After Confirmed Alarms Reset Required After All Alarms
5 Normal Sounder Operation French Sounder Operation
6 Do Not Allow Zone Restorals After Reset Allow Zone Restorals After Reset
7
8
Reserved for Future Use. Do Not Alter.
Shaded = Default
*IMPORTANT NOTE ON ENGINEER RESET
Please note that if the below options are both turned ON; an Engineer Reset is only needed for any
TAMPER ALARMS.
A user code will be able to reset ALL OTHER ALARMS.
O
PTION
N
UMBER
3
=
E
NGINEER
R
ESET
E
NABLED
O
PTION
N
UMBER
4
=
R
ESET
R
EQUIRED
A
FTER
A
LL
A
LARMS