Matrix 424/832/832+ LCD Programming Manual
RINS916-6 Page 45
15.2 Arm Mode A Events Send Options (Function 701)
15.3 Arm Mode B Events Send Options (Function 702)
15.4 Arm Mode C Events Send Options (Function 703)
15.5 Arm Mode D Events Send Options (Function 704)
Programming for Arm Mode A is shown.
Press .
This starts the function
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current options are displayed.
Select any option by using the and
keys, or use the – keys to select that
option directly.
Press to toggle the option
ON
or
OFF
.
Press to accept the options.
There are 8 options
SYSTEM OPTIONS 1
OPTION 8 ON
SYSTEM OPTIONS 1
OPTION 7 ON
SYSTEM OPTIONS 1
OPTION 6 ON
SYSTEM OPTIONS 1
OPTION 5 ON
SYSTEM OPTIONS 1
OPTION 4 ON
SYSTEM OPTIONS 1
OPTION 3 ON
SYSTEM OPTIONS 1
OPTION 2 ON
ARM A SIGNALS
OPTION 1 ON
№ OPTION OFF OPTION ON
1 Alarms are Not Sent Alarms are Sent
2 PA Alarms are Not Sent PA Alarms are Sent
3 Fire Alarms are Not Sent Fire Alarms are Sent
4 Maintenance Events are Not Sent Maintenance Events are Sent
5 Open/Close Events are Not Sent Open/Close Events are Sent
6 Medical Alarms are Not Sent Medical Alarms are Sent
7 Confirmed Alarms are Not Sent Confirmed Alarms are Sent
8* Omit (Bypass) Events are Not Sent Omits (Bypass) Events are Sent
Shaded = Default
*NOTE: Italy – Omit (Bypass) Events MUST be reported for all Arm Modes to comply with
CEI79.
Belgium – Omit (Bypass) Events MUST be reported for all Arm Modes to comply
with T014.