Matrix 424/832/832+ LCD Programming Manual
RINS916-6 Page 33
11.4 Exit Time (Function 503)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current exit time is displayed.
Example shows 20
seconds
ENTER EXIT TIME
20
Enter 2 digits for the new delay (00 – 99).
Example shows 10
seconds
ENTER EXIT TIME
10
Press to accept the changes.
NOTE: Default is 20 seconds.
11.5 Final Exit Delay (Function 504)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current exit delay time is displayed.
Example shows 07
seconds
SETTLE TIME ?
07
Enter 2 digits for the new time (00 – 99).
Example shows 05
seconds
SETTLE TIME ?
05
Press to accept the changes.
NOTE: Default is 7 seconds.
11.6 Auto Arm Commence Time (Function 505)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current time is displayed.
Example shows Auto
Arm disabled (0000)
ENTER START TIME
_0000
Enter 4 digits for the new commence time (0000
– 2359, 24-hour format).
NOTE: The time is automatically accepte
after entering the 4
th
digit.
Example shows 12:26
PM
ENTER START TIME
1226
NOTE: Default is 0000 (Auto Arm disabled).
NOTE: Italy – If Auto Arm is to be used, “Allow Arm If H,I,P,F,M,T Zone Open” must be set
to “Yes”, and “Immediate Zone Open On Exit” must be set to “Causes Alarm” (System
Options 2, page 11) in order to comply with CEI79.