Matrix 424/832/832+ LCD Programming Manual
Page 48 RINS916-6
15.8 MX-VOICE Module Support (Function 707)
Press .
This starts the function
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
Enter the alarm type (1 – 8)
Valid alarm types are:
1 = Alarm
2 = PA
3 = Fire
4 = Maintenance
5 = Open/Close
6 = Medical Alarm
7 = Confirmed
8 = Omit
This display is quickly
followed by the next
ENTER ALARM TYPE
_
ENTER ALARM TYPE
_6
The current voice message number is displayed.
Example shows voice
message 2
ASSIGN VOICE MSG
02
Enter 1 digit to assign the voice message (1 –
8).
Example shows voice
message 1
ASSIGN VOICE MSG
01
Press to accept the changes.
NOTE: By default all alarm types activate voice message 1, except Close events, which
activate voice message 2.
15.9 Number of Voice Dials (Function 709)
Press .
This starts the function
ENTER VOICE QTY
01
Enter 1 digit to assign the new number of voice
dials (1 – 8).
NOTE: A leading zero is always shown.
Example shows 3 voice
dials
ENTER VOICE QTY
03
Press to accept the changes.
NOTE: Default is 1.