Matrix 424/832/832+ LCD Programming Manual
RINS916-6 Page 39
13.3 Digital Communicator Options 1 (Function 602)
Press .
This starts the function
DIGI COMM OPT 1
OPTION 1 OFF
The current partition options are displayed.
Select any option by using the and
keys, or use the – keys to select that
option directly.
Press to toggle the option
ON
or
OFF
.
Press to accept the options.
There are 6 options
SYSTEM OPTIONS 1
OPTION 6 ON
SYSTEM OPTIONS 1
OPTION 5 OFF
SYSTEM OPTIONS 1
OPTION 4 ON
SYSTEM OPTIONS 1
OPTION 3 OFF
SYSTEM OPTIONS 1
OPTION 2 OFF
DIGI COMM OPT 1
OPTION 1 OFF
№ OPTION OFF OPTION ON
1 Disable Telephone Line Monitoring Enable Telephone Line Monitoring
2 Standard Handshake Filter Wide Handshake Filter
3 Tone Dial Pulse Dial
4 Disable AMC Enable AMC
5 Reporting Events are Low Priority Reporting Events are High Priority
6 Disable Send Open After Alarm Enable Send Open After Alarm
7
8
Reserved for Future Use. Do Not Alter.
Shaded = Default
13.4 Test Dial Time (Function 603)
Press .
The current test dial time is displayed.
Example shows 12:43
PM
ENTER TIME
_1234
Enter 4 digits for the new test dial time (0000 –
2359, 24-hour format, 0000 =- disabled).
NOTE: The time is automatically accepte
after entering the 4
th
digit.
Example shows 16:00
(4PM)
ENTER TIME
1600
NOTE: Default is 0000 (disabled).