Matrix 424/832/832+ LCD Programming Manual
RINS916-6 Page 63
Q EEE English Equivalent Matrix System Events PP NNN
3 403 Automatic Close (Arm) by Inactivity ot Auto Arm Timers 01-04 000
3 403 Automatic Close (Arm) On Power Up 01-04 099
1 or 3 409 Keyswitch Open (Disarm) / Close (Arm) by Keyswitch Zone 01-04 000
Group 6: MEDICAL ALARMS
1 or 3 100 Personal Emergency Medical Alarm / Restoral from Keypad 01-04 000
1 or 3 100 Personal Emergency Medical Zone – Alarm / Restoral 01-04 001-032
Group 7: CONFIRMED ALARMS
1 or 3 139 Confirmed Alarm Alarm code send after activation of any 2 zones within
one arm period
01-04 000
Group 8: OMIT (BYPASS)
1 570 Zone Bypass Normal Zone Omitted (Bypassed) On Arm or Auto
Rearm
01-04 001-032
1 571 Zone Bypass Fire Zone Bypasses on Arm 01-04 001-032
1 572 24 Hour Bypass 24 Hour Zone Omitted (Bypassed) On Arm or Auto
Rearm
01-04 001-032
ABORT
1 406 Open After Alarm Abort / Cancel with User Code after Alarm 01-04 000
TEST DIALS
1 602 Periodic Periodic Test Call 01 000
1 or 3 250 Keybox & Patrol Keybox Zone – Opened / Closed 01-04 001-032
1 406 Open After Alarm Abort / Cancel with User Code after Alarm 01-04 000
KEYBOX & PATROL
1 or 3 250 Keybox & Patrol Keybox Zone – Open (Disarm) / Close (Arm) 01-04 001-016
+
Message string of CID: [AAAA] [CC] [Q] [EEE] [PP] [NNN] [m]
[AAAA] Account Number
[CC] Reporting Format (18 for CID)
[Q] Event Qualifier: 1 = New Event or Opening, 3 = New Restore or Closing
[EEE] Digital Event Code
[PP] Partition Number
[NNN] Zone Number / User Number / Component Qualifier
[m] Checksum