Matrix 424, 832, 832+ Installation Manual
Page 30 RINS918-6
2.12.4 Double End of Line Zones Connection to Matrix
NOTE 1: Terminal connections to Matrix 424 and 832+ are the same as to a Matrix 832.
NOTE 2: The wiring shown at the bottom of the diagram allows 24 hour tamper monitoring of all
detectors in one zone and of the zone circuit, with retaining the two-wire loop. It is not
recommended to connect more than 6 detectors in this way (not more than 7 x 4K7±5% resistors).
More than 6 detectors may be connected to one zone in this way only if simultaneous activation of six
or more detectors is improbable (in disarmed mode also), otherwise it will cause a tamper alarm.
Spare
A
LARM
Magnetic
Contact
Zone 1
SUPPLY
ALARM
TAMPE
R
PIR
Detector
Zone 8
+AUX-
SUPPLY
ALARM
T
AMPE
R
PIR
Detector
Zone 2
+AUX-
MATRIX 832 PCB
Spare
A
LARM
Magnetic
Contact
Is the first
in the zone
SUPPLY
A
LARM
T
A
MPE
R
PIR
Detector
+AUX-
SUPPLY
A
LARM
T
AMPE
R
PIR
Detector
+AUX-
Zone 1
Is the second
in the zone
Is the last
in the zone
Connection of several detectors to one zone
4
K
7
4
K
7
4
K
7
4
K
7
4
K
7
4
K
7
4
K
7
4
K
7
4
K
7
4
K
7

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals