Matrix 424, 832, 832+ Installation Manual
RINS918-6 Page 33
2.13.3 External Sounder Connection to Matrix 832+
2.13.4 TWIN ALERT Internal Sounder Connection to Matrix 424
MATRIX 424 PCB
TWIN ALERT
T
win Alert must be connected to Matrix panel as
illustrated.
PGM3 must be programmed as “Twin Alert”.
In this illustration PGM1 should be programmed as
External Bell”.
PGM1 = BA = BELL OUTPUT
PGM3 = SPK = TWIN ALERT SPEAKER OUTPUT
MATRIX 832+ PCB
BELLE
DECIBELL
T
he BELLE or DECIBELL may be connected usin
g
different programmable outputs.
In this instance PGM1 is programmed as “External
Bell” and PGM2 is programmed as “Follow Strobe”.
PGM1 = BA = BELL OUTPUT
PGM2 = STB = STROBE TRIGGER