Matrix 424, 832, 832+ Installation Manual
Page 40 RINS918-6
3.4 ICON Keypad Indication
Rest
of the World
Denmark, Norway,
Finland & Sweden
Steady
Correct AC & DC
power sources
AC power is OK
Blinking
Indicates DC
source (battery)
fault
Indicates an AC
fault
Extinguished
Indicates AC
fault / no power
to panel
No power to the
panel
Steady
In Log display qualifies the alarm type
/ Day mode indicates activated test
zone
Blinking
Active alarm in FTA mode
Steady
OK to Arm, no open zones
Fast Blinking
A latched alarm is active (Denmark,
Norway, Finland & Sweden only)
Blinking
Select partitions to arm or disarm /
Programming function is active
Extinguished
No active alarms
Extinguished
One or more open zones or all
assigned partitions are already armed
Steady
The panel is disarmed
Steady
The panel is armed
Blinking
Keypad is in user menu mode
Blinking
Indicates the panel is arming with
omitted zones
Extinguished
The panel is not disarmed
Extinguished
The panel is not armed
Steady
Indicates a PA alarm condition
(used in log display)
Steady
Indicates a Fire alarm condition
(used in log display)
Blinking
Indicates a PA alarm condition in FTA
mode
Blinking
Indicates a Fire alarm condition in
FTA mode
Extinguished
No PA active
Extinguished
No Fire alarm active
Steady
Indicates a tamper condition
(used in log display)
Steady
Indicates a System Fault
Blinking
Indicates a tamper condition in FTA
mode
Blinking
Keypad is in Engineer Mode
Extinguished
No tamper alarm active
Extinguished
No Fault active
= Partition 1,
= Partition 2,
= Partition 3,
= Partition 4
Steady
Partition is Armed
Fast Blinking
Partition is in Alarm
Blinking
Partition is Arming
Extinguished