Matrix 424, 832, 832+ Installation Manual
RINS918-6 Page 47
BUS DEVICE MAX. NUMBER
LCD Keypad 4
ICON Keypad 4
MX-PROX Proximity Reader 4
MX-RIX8DW Remote Wireless Expander 2
MX-RIX Remote Zone Expander with Zone Analyser 2
MX-IX On-board Zone Expander 1
MX-ROX Output Expander 1
4.3 Technical Specification
4.3.1 Main Control Panel
ZONES PROGRAMMABLE OUTPUTS (PGM)
Zone Loop Current 0.54mA – Max. PGM 1 Relay contacts, 30V@3A
DEOL Zone Activation Resistance
PGM 2
Short Circuit <800 Matrix 424/832 Open collector, 12V@200mA
Normal >800 to <6k Matrix 832+ Relay contacts, 30V@3A
Activated >6k to <36k PGM 3 Open collector, 12V@200mA
Open Circuit >36k PGM 4* Open collector, 12V@10mA
NC Zone Activation Resistance
*NOTE: PGM 4 is designed for triggering ONLY.
Normal <4k
PCB POWER SUPPLY
Activated >4k Power Input 17Vac
Doubled Zone Activation Resistance
Transformer Rating
Both Zones Normal >2k to <6k Plastic Case 21VA
Both Zones Activated >11k to <35k Metal Case (832+) 44VA
Zone n Activated >8k to <11k EN50131-6 Type A
Zone n+16 Activated >6k to <8k Voltage Output 13.6Vdc@1A regulated
Zone Doubled: Tamper Activated <2k or >35k Voltage Range Max. 13.8V Min. 10.5V
Zone Response Time
Ripple 1% Max.
Standard Zones 300ms Panel Current Requirement 200mA
Fast Zones 100ms Constant Current Output
Only Zone 1 Fast 30ms Plastic Case 600mA
Zone Protection (832/832+ only) 18V Varister Metal Case (832+) 1.1A
Total Current Output
DIGITAL COMMUNICATOR Plastic Case 900mA (for 15mins)
Telephone Line Monitoring Yes Metal Case (832+) 1.8A (for 15mins)
Telephone Connection Allows other tel. on the line PCB FUSES
Digital Communicator Analogue Line AC Fuse Quick blow 2A – F2L
Lightning Protection 6.75kV / 125A Aux Fuse Quick blow 1A – F1L
Aux1 (Bell) Fuse (424 - N/A) Quick blow 1A – F1L
BATTERY Keypad Fuse (832+ only) Quick blow 1A – F1L
Type 12V Lead acid rechargeable Battery Fuse Slow blow 5A – T5H
Battery Charge Min 6V Mains Fuse T250mA
Max Battery Charge Current
Plastic Case 350mA
MECHANICAL
Metal Case (832+) 800mA Dimensions
Battery Charge Method
The Matrix panel monitors the
voltage of the battery and
commences charging when the
battery reaches 12.8V ± 5%
and disables charging when it
reaches 13.6V ± 5%
Plastic Case 340 x 280 x 94.5 mm
Metal Case (832+) 389.5 x 314.5 x 96.2 mm
Security Grade 2 - Metal (832+), N/A - Plastic
Environmental Class 2 - Metal (832+), N/A - Plastic
TEMPERATURE

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals