Note:
ASpeedRunCalibrationcanonlybeperformedifSOGdataisavailable
.
Ifrequired,furthercalibrationpointscanbeaddedandacalibrationfactorcanbeappliedtofurther
alignthelogspeedwithactualvesselspeed.
iT
C-5Smart(DST)Speedpod
SOGNoSOGSOGNoSOGSOGNoSOG
1P
ointSpeed
Calibration
SpeedRun
Calibration
ManualCalibration
1P ointSpeedCalibration
Toperforma1PointSpeedCalibrationfollowthestepsbelow.
Prerequisites:
•ForbestresultsSOGdatashouldbeavailable,oranalternativemethodofestimatingvesselspeed
mustbeused(e.g.vesselspeedcanbeestimatedusingNauticalMeasuredMileMarkersor
similarlandmarksofaknowndistanceapart).
•Y ouwillneedtobeunderway,withsufficientspacetomaneuverunhindered.
•Inordertoachieveaccurateresults,waterconditionsmustbecalmwithzerotideandzerocurrent.
Withafavoritepagedisplayed:
1.Pressthe Menubutton.
2.SelectSet-up.
3.SelectTransducersSet-up.
4.Select
Continue.
Thedisplaywillsearchforandshowalistofconnecteddevices.(i.e.iTC-5,DSTortransducer
pod)
5.Selectthedevicethatthetransduceryouarecalibratingisconnectedto.
Alistofavailabletransducerdataisdisplayed,
6.
(1)
Select
Speed.
Important:
(1)S teponlyapplicabletoiTC-5.
7 .Select SpeedCalibration.
8.SelectAdjustspeedup/down.
The1PointSpeedCalibrationpageisdisplayed.
26