Thermalert GP Series Operator’s Manual 11
O
N
L
C
F
Thermalert GP
Figure 6: Device Selection Display
2.4.2 Device Selection
Six device types can be connected to the electronics enclosure. Complete the
following procedure to set the electronics to the appropriate device.
1. From the temperature/value display, press and hold , press , then
release them both. A display similar to Figure 6 appears. (The “H” will
be followed by numbers designating the device type. See Step 2.)
2. Press the and buttons to change the number on the display to the
appropriate head type.
Head types are as follows:
H001 = Raytek GPR/GPS Heads
H002 = Raytek GPM Head
H003 = Raytek CI3 Head
H004 = 0 - 5V inputs
H005 = 4 - 20mA inputs
H006 = Thermocouple inputs
Note that all head types except H003 have additional display settings (as
shown on the next page).