KrosFl Systems
User Guide
13
IF.UG.IM_R1
10. Never exceed the operating limits detailed in this user guide or on the System label.
Operating the System outside of the stated limits may result in equipment damage and
personal injury.
11. Using process or cleaning fluids that are incompatible with the flow-path materials can
damage the System.
12. Do not connect components that are not rated for the System, this includes owner-supplied
cassettes, flow-paths, hoses, tanks, and any other accessories.
13. Drain connections must be connected unrestrictedly to drain header and maintained at
atmospheric pressure. Any valves in this path shall be locked open with suitable owner-safe
procedures in place. Avoid pooling in drain lines.
14. Use a harmless fluid, for example water, during startup to enable detection of leaks without
exposure to hazardous fluids.
15. Set alarm limits within the specifications noted in this User Guide or within the limits
recommended in the software.
16. When alarms are triggered, address all of them one-by-one before continuing with System
operation.
17. Due to a noise level of 80 decibels or greater, ear protection is required when the System
pumps are operated at a speed of greater than (>) 6000 RPM.
18. For Systems equipped with an optional UV photometer, note the following safety guidelines:
WARNING: The photometer can emit light from ≈200 1100nm . Hazardous UV and
IR radiation are emitted from the unit. Never directly stare into the source/return
ports on the photometer or the fiber optic cables, as this can cause eye damage. The
viewer-related risk is dependent on how the users install and use the product.
Ensure that both ends of the fiber optic cables (photometer and flow cell
connections) are properly secured (firmly hand tight) before powering on the
photometer.
The photometer should always be powered off when handling the fiber optic cables.
If you must handle the fibers when the unit is powered on, protective eyewear must
be worn.
In the event of product failure, do not attempt to open the unit or replace the LED.
There are no user-serviceable parts.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REPLIGEN KrosFlo SYITF-2000 and is the answer not in the manual?

REPLIGEN KrosFlo SYITF-2000 Specifications

General IconGeneral
BrandREPLIGEN
ModelKrosFlo SYITF-2000
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals