Registration
Horiz. Tray1
Adjusts the horizontal registration for tray 1. If the
machine settings are reset to the factory defaults, this
value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Vert.Tray1
Adjusts the vertical registration for tray 1. If the machine
settings are reset to the factory defaults, this value does
not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Horiz Bypass Tray
Adjusts the horizontal registration for the bypass tray. If
the machine settings are reset to the factory defaults, this
value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Vert Bypass Tray
Adjusts the vertical registration for the bypass tray. If the
machine settings are reset to the factory defaults, this
value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Horiz.Dup Back
Adjusts the horizontal registration for the back side in
duplex mode. If the machine settings are reset to the
factory defaults, this value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Vert.Dup Back
Adjusts the vertical registration for the back side in duplex
mode. If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Counter Reset Resets counters to factory defaults.
Clear log Clears the error and the jam counter logs.
Reset Transfer Resets the transfer unit life counter.
Reset Fuser Resets the fusing unit life counter.
Reset 2nd Resets the 2nd transfer unit (transfer roller) life counter.
Maintenance ID
00* – 7F
Displays the current maintenance ID number.
Do not change this setting (Designed for Factory Use).
Service Menu