EasyManuals Logo
Home>Roland>Synthesizer>Fantom XR

Roland Fantom XR User Manual

Roland Fantom XR
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #216 background imageLoading...
Page #216 background image
216
Effects List
The Fantom-XR’s Chorus effect unit can also be used as a stereo
delay unit.
These settings allow you to select chorus or delay, and the
characteristics of the selected effect type.
If you specify the delay time as a note value, slowing down the
tempo will not change the delay time beyond a certain length.
This is because there is an upper limit for the delay time; if the
delay time is specified as a note value and you slow down the
tempo until this upper limit is reached, the delay time cannot
change any further. This upper limit is the maximum value that
can be specified when setting the delay time as a numerical
value.
note:
fig.MFX-note2.e
Chorus Parameters
Parameter
Value Description
Chorus
Type
0 (OFF),
1 (CHORUS),
2 (DELAY),
3 (GM2 CHORUS)
Selects either Chorus or Delay.
0 (OFF): Neither Chorus or Delay
is used.
1 (CHORUS): Chorus is used.
2 (DELAY): Delay is used.
3 (GM2 CHORUS): GM2 Chorus
is used.
Type: 1 (CHORUS)
Rate
0.05–10.00 Hz, note Frequency of modulation
Depth 0–127 Depth of modulation
Pre Delay 0.0–100.0 ms
Adjusts the delay time from the direct
sound until the chorus sound is heard.
Feedback 0–127
Adjusts the amount of the chorus
sound that is fed back into the effect.
Filter Type OFF, LPF, HPF Type of filter
OFF: no filter is used
LPF: cuts the frequency range
above the Cutoff Freq
HPF: cuts the frequency range
below the Cutoff Freq
Cutoff Freq 200–8000 Hz Basic frequency of the filter
Phase 0–180˚ Spatial spread of the sound
Type: 2 (DELAY)
Delay Left
0–1000 ms, note Adjusts the delay time from the di-
rect sound until the delay sound is
heard.
Delay Right
Delay Center
Center
Feedback
-98–+98 % Adjusts the proportion of the delay
sound that is fed back into the ef-
fect. Negative (-) settings will invert
the phase.
HF Damp 200–8000 Hz,
BYPASS
Adjusts the frequency above which
sound fed back to the effect will be
cut. If you do not want to cut the
high frequencies, set this parameter
to BYPASS.
Left Level 0–127 Volume of each delay sound
Right Level
Center Level
Type: 3 (GM2 CHORUS)
Pre-LPF
0–7 Cuts the high frequency range of
the sound coming into the chorus.
Higher values will cut more of
the high frequencies.
Level 0–127 Volume of the chorus sound
Feedback 0–127
Adjusts the amount of the chorus
sound that is fed back into the effect.
Delay 0–127 Adjusts the delay time from the di-
rect sound until the chorus sound is
heard.
Rate 0–127 Frequency of modulation
Depth 0–127 Depth of modulation
Send Level
To Reverb
0–127
Adjusts the amount of chorus sound
that will be sent to the reverb.
(Double note)(Dotted whole note),
(Dotted half note),
(Dotted thirty-second note),
(Whole note),
(Double-note triplet),
(Sixteenth-note triplet),
(Thirty-second note),
(Sixty-fourth-note triplet), (Sixty-fourth note), (Thirty-second-note triplet),
(Dotted eighth note),(Quarter-note triplet),(Eighth note),
(Half-note triplet),(Quarter note),
(Dotted quarter note),
(Whole-note triplet),
(Half note),
(Sixteenth note),
(Eighth-note triplet),
(Dotted sixteenth note),
Fantom-XR_r_e.book 216 ページ 2006年4月4日 火曜日 午前10時14分

Table of Contents

Other manuals for Roland Fantom XR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roland Fantom XR and is the answer not in the manual?

Roland Fantom XR Specifications

General IconGeneral
BrandRoland
ModelFantom XR
CategorySynthesizer
LanguageEnglish

Related product manuals