1.3 ^SSTN Remote-SAT Notification
Proactive
Commands
Every time the SIM application issues a proactive command, via the ME, the TA
will receive a notification. This indicates the type of proactive command issued.
AT^SSTGI must then be used by the TA to request the parameters of the
proactive command from the ME.
Upon receiving the ^SSTGI response from the ME, the TA must send AT^SSTR
to confirm the execution of the proactive command and provide any required user
response e.g. selected menu item.
Unsolicited result code
^SSTN: <cmdType>
Parameters
<cmdType>
Proactive command ID, see Table 1- Command Type Identifiers
Note:
Only one proactive command can be ongoing at any one time.
Terminate
Proactive
Command
When the SIM application has issued a proactive command, via the ME, to the
TA, it is possible that this command must be terminated. The ^SSTN Unsolicited
Result Code is sent but with a different command type (add terminate offset 100),
to indicate the termination of the specified command.
The state changes to idle.
The TA should then avoid sending any further commands related to the
terminated proactive command, e,g. AT^SSTGI or AT^SSTR.
Unsolicited result code
^SSTN: <cmdTerminateValue>
Parameters
<cmdTerminateValue> is defined as <cmdType> + terminate offset. The
terminate offset equals 100.
Terminate proactive command ID, see Table 1- Command Type Identifiers
SIM
Application
returns to
main menu
Notification to the TA when the SIM Application has finished a command cycle
and again enters its main menue, which was transferred with an URC ^SSTN: 37
(SET UP MENU) at start up.
This URC should be used to open this menue on the sreen.
The TA does not need to respond directly, i.e. AT^SSTR is not required.
Unsolicited result code
^SSTN: <254>
Reference
Siemens
Note

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MC35 Terminal and is the answer not in the manual?

Siemens MC35 Terminal Specifications

General IconGeneral
BrandSiemens
ModelMC35 Terminal
CategoryModem
LanguageEnglish

Related product manuals