Device maintenance and repair
7.3 Removing and installing hardware
SIMATIC IPC847E
144 Operating Instructions, 10/2018, A5E43920357-AA
7.3.8
Replacing the processor
Requirement
The device is fully disconnected from the line voltage, see "Switching off the device
(Page 60)".
The device is open, see important information in "Open the device (Page 89)".
An original spare part, i.e. a processor of the same type.
Only an approved processor is permitted to be installed on the motherboard.
NOTICE
Damage to the processor
If the processor is operated with a higher clock frequency than permitted, it can be
destroyed or cause loss of data.
Operate the processor only at a clock frequency that is equal to or less than the
permitted clock frequency.
Procedure
1. Remove the bus board, see "Replacing the bus board (Page 143)".
2. Remove the heat sink of the processor.
3. Unlock the socket and lift the socket cover.
4. Remove the processor.
5. Place the new processor in the socket.
During positioning, make sure to take the highlighted arrow on the processor into
consideration.
6. Lock the processor in place.
7. Install the heat sink of the processor again.
8. Install the bus board again.

Table of Contents

Other manuals for Siemens SIMATIC IPC847E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC847E and is the answer not in the manual?

Siemens SIMATIC IPC847E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC847E
CategoryIndustrial PC
LanguageEnglish

Related product manuals