Operating the device
5.4 Operating RAID systems
SIMATIC IPC847E
82 Operating Instructions, 10/2018, A5E43920357-AA
5.4.6
Data synchronization in the RAID system
NOTICE
Danger of incorrect operations on machine and plant: delayed system reaction during data
synchronization
Data is synchronized if a drive fails.
The system can respond with a delay depending on the size of the drive and system load.
In extreme cases, the execution of keyboard, mouse or touch screen commands may be
briefly delayed.
The result may be faulty operations of the machine or plant.
Do not operate safety-critical functions during synchronization of a drive. Stable system
statuses are only achieved after successful completion of synchronization.
Duration of data synchronization
The synchronization process may take quite some time, e.g. several hours, with extremely
high drive load even days.
Guide value for the duration of data synchronization:
< 3 h with 90% HDD system load and RAID5 with HDD 1 TB.
In addition, system performance may be limited in the case of a manually started
maintenance operation until completion of the maintenance phase.

Table of Contents

Other manuals for Siemens SIMATIC IPC847E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC847E and is the answer not in the manual?

Siemens SIMATIC IPC847E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC847E
CategoryIndustrial PC
LanguageEnglish

Related product manuals