Fault Fault cause (see "Fault causes and remedial measures"
key table)
Radial vibrations N O P Q S
Axial vibrations P R S
"Fault causes and remedial measures" key table
No. Fault cause Remedial measures
A Overload Reduce load
B Interruption of a phase in the sup‐
ply cable / motor winding
Check the frequency converter and supply cables, measure
the winding resistances and insulation resistances, repair af‐
ter consultation with manufacturer
C Interrupted phase in the feeder ca‐
ble after switching on
Check the frequency converter, supply cables and the wind‐
ing resistances
D Converter output voltage too high,
frequency too low
Check the settings on the frequency converter, perform au‐
tomatic motor identi󹪝cation
F Winding short-circuit or phase
short-circuit in stator winding
Measure the winding resistances and insulation resistances,
repair after consultation with the manufacturer, if required,
replace the motor
I Heat dissipation impeded by dirt Clean the surface of the drives and ensure that the cooling air
can 󹪞ow in and out unimpeded
Cooling air inlet/outlet is blocked
by foreign bodies
Remove the reason for the blocking and ensure that the cool‐
ing air can 󹪞ow in and out unimpeded
J Fan motor does not start Check that the fan motor functions correctly
K Insu󹪟cient shielding for motor
and/or encoder cable
Check the shielding and grounding
CC
W
Excessive drive controller gain Adjust the controller
M Rotating parts are grinding Determine cause and adjust parts
Foreign bodies inside the motor Replace the motor
Bearing damage Replace the motor
N Rotor not balanced Replace the motor
O Rotor out of true, shaft bent Consult the manufacturer
P Poor alignment Align motor set, check coupling
Q Coupled machine not balanced Re-balance coupled machine
R Shocks from coupled machine Check coupled machine
S Fault originating from the gearbox Adjust/repair gearbox
If the fault still cannot be resolved after taking the measures listed above, then please
contact the sales partner responsible or the Siemens Service Center.
Faults and their recti󹪝cation
10.11FT2 faults
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
104 Operating Instructions, 12/2023, A5E50610821B AF