ALC700 Series Light Tower Set Controller
ALC700 Series Light Tower Set Controller 2018-03-02 Version 1.4 Page 15 of 51
5.4 SUNRISE/SUNSET MODE
If the city information haven’t been set when select this mode, users should connect PC and
ALC700 controller using USB or RS485 communication line and set the city information first.
The procedures as following:
Open test softwareedit configurationset sunrise/sunsetselect city/user-defined city
(longitude, latitude and time zone) download the configuration
A. Press its indicator light on, and controller enters Auto mode. Meanwhile, the panel
display Auto Mode Select (Fig 1); Press and to select 03 Sunrise/Sunset Mode
and press or to confirm (Fig 2); Press and to select 01
Sunrise/Sunset Start and press or to confirm (Fig 3).
B. When there are 10s left from start time (controller’s current time can be set via utility
computer software), audible alarm relay is active (if configured). When start time is up, light
tower set begin cranking and flashlight is twinkling (if configured). Stop delay will be
displayed on the first line (Fig 4).
AUTO MODE SELECT
01 AUTO TIMER MODE
02 AUTO SMS MODE
03 SUNRISE/SUNSET MODE
Fig 1
Fig 3
Fig 4
STOP DELAY 07:25:00
START TIME 17:26:00
CURRENT TIME 17:26:02
CRANKING 5s
SUNRISE/SET ACTION
START TIME 17:26:00
CURRENT TIME 12:05:18
GENERATOR AT REST
Fig 2
SUNRISE/SET ACTION
01 SUNRISE/SUNSET START
02 SUNRISE/SUNSET STOP