ALC700 Series Light Tower Set Controller
ALC700 Series Light Tower Set Controller 2018-03-02 Version 1.4 Page 44 of 51
8.12 SMS (ORDER AND REPLY)
Stop mode order; set controller into stop mode; Stop
running light tower set;
Reply:SMS STOP OK
Start order; can control light tower set to start;
Reply:SMS START OK
Sunrise/sunset mode order
Reply:SMS SUNRISE/SET START OK
SMS TIME SET
13-01-04 20:13:14
Set the time of controller;
Set form:YY-MM-DD HH:MM:SS
Reply:TIME SET OK YY-MM-DD HH:MM:SS
Inquiry order; inquiry the current status of controller.
Reply:GENSET AT REST or
GENSET IS RUNNING
YY-MM-DD HH:MM:SS
Inquiry all sensors’ information
Reply:all sensors’ information and the real time
Inquiry oil pressure sensor’s information
Reply:oil pressure
Inquiry temperature sensor’s information
Reply:engine temperature
Inquiry fuel level sensor’s information
Reply:fuel level sensor’s information
NOTE: Its national and area’s cods must be added, e.g. Chinese number should be set as
+8613666666666 or 008613666666666.
NOTE:The SMS orders are active only when GSM modem is enabled. In addition, the
1~3 SMS orders are active only in AUTO DIAL-UP MODE.
NOTE:The controller will send alarm information to preset telephone automatically when
shutdown alarm or trip alarm occur.
8.13 SUNRISE/SET SET
Users can select corresponding city or define city’s information (longitude, latitude and time
zone) via utility software and download the information into controller; then controller will run in
auto sunrise/set mode.
NOTE:The information can be configured by software via PC only.