- 17 -
No.SFOD-OMT0010-B
(2) Setting parameters
Set the parameters such as for valid axis and electronic gear.
Check the parameters below and change them if necessary. For other items, refer to section
7.
Settings and Data Entry
.
Maximum step data. Change if necessary.
Set the validity of the axes. Set "0" (invalid) when no
actuator is connected. Set "1" (valid) when connected.
The order for axes to return to origin. The order is assigned
from 1 to 4. Multiple axes are possible to return to origin
simultaneously by setting the same order number.
Define the Electronic Gear.
Undefined parameter No.11: Electronic gear (numerator)
Undefined parameter No.12: Electronic gear (denominator)
When interpolation is performed for actuators of
different lead, the travel distance per pulse must be the
same. Otherwise do not change the distance.
Set the electronic gear for Axis 2, 3 or 4 so that the travel
distance for all of them are the same as Axis 1.
[Setting example]
Set Axis 2 and 3 so that the travel distance becomes
2.5mm per 800 pulse.
Electronic Gear ratio
= Lead of Axis 1/ Lead of Axis 2(or Axis 3)
=2.5mm/5mm (or 2.5mm/10mm)
=25/50 (or 25/100)