8.2 Positioning Operation
When the "Pushing selection" step data is "0" for a Positioning operation.
The actuator moves to the target position specified by the step data “Position.”
Example) After a Return to origin, move the 4 axes from the origin to a 50mm position at 100mm/s
(Step No.1). Next, move the actuator to a 100mm position by moving it 5 times consecutively, 10mm
at a time, at a speed of 50 mm/s (Step No. 2).
Step Data Setting Example
Step
No.
Axis
Movement
mode
Speed
(mm/s)
Position
(mm)
Acceleration
(mm/s
2
)
Deceleration
(mm/s
2
)
Pushing
Selection
Area 1
(mm)
Area 2
(mm)
In-position
(mm)
1
Axis 1
ABS
100
50.00
1000
1000
0
0
0
0.5
Axis 2
ABS
100
50.00
1000
1000
0
0
0
0.5
Axis 3
ABS
100
50.00
1000
1000
0
0
0
0.5
Axis 4
ABS
100
50.00
1000
1000
0
0
0
0.5
2
Axis 1
INC
50
10.00
1000
1000
0
0
0
0.5
Axis 2
INC
50
10.00
1000
1000
0
0
0
0.5
Axis 3
INC
50
10.00
1000
1000
0
0
0
0.5
Axis 4
INC
50
10.00
1000
1000
0
0
0
0.5
Actuator
Origin
position
Step Data
"Speed"
Step Data
"In-position"
Target position
-> Step Data "Position"
M
Motor
Load
Positioning Operation (Example)
Positioning operation [Speed/Position] (Example)
Speed
Set speed
Set
acceleration
speed
Actual
acceleration
speed
Set
deceleration
speed
Actual
deceleration
speed
Target position
Time
In-position
INP output

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks JXC73 Series and is the answer not in the manual?

SMC Networks JXC73 Series Specifications

General IconGeneral
BrandSMC Networks
ModelJXC73 Series
CategoryController
LanguageEnglish

Related product manuals