Technical Data
Technical Data
4.3 Battery (apply to version D/M)
4.4 Efficiency, Safety and Protection (apply to version D/M)
4 Technical Data
4.1 DC Input (apply to version D/M)
22
23
Integrated
Integrated
YES
YES
YES
YES
YES
Frequency Shift
YES
YES
YES
MPPT efficiency
European efficiency
Maximum efficiency
Model
X1-Hybrid-3.0 X1-Hybrid-3.7 X1-Hybrid-6.0
99.9%
97.0%
97.6%
97.0%
99.9%
97.0%
97.6%
97.0%
99.9%
97.0%
97.6%
97.0%
Max. battery charge efficiency
(PV to BAT) (@ full load)
Max. battery discharge efficiency
(BAT to AC) (@ full load)
97.0% 97.0% 97.0%
X1-Hybrid-7.5
99.9%
97.0%
97.6%
97.0%
97.0%
Security & Protection
DC SPD Protection
AC SPD Protection
Over/under voltage protection
Grid protection
DC injection monitoring
Back feed current monitoring
Residual current detection
Active anti-islanding method
Over load protection
Over heat protection
Array insulation resistance detection
Battery type
Battery voltage range [d.c. V]
Max. continuous
Communication interface
Reverse connection protection
Lithium batteries
80-480
30
CAN/RS485
Yes
Model
X1-Hybrid-3.0 X1-Hybrid-3.7 X1-Hybrid-6.0 X1-Hybrid-7.5
4.2
AC Output / Input (apply to version D/M)
Nominal AC voltage [a.c. V]
Frequency [Hz]
Power factor range
Total harmonic distortion (THDi)
3000
3300
3680
3680
AC Output
220/ 230/ 240 (180 to 270)
50/60
0.8 leading - 0.8 lagging
< 2%
AC Input
6300
3000
7360
3680
9200
220/230/240 (180 to 270)
50/60
Max. apparent power [VA]
Rated AC power [W]
Nominal AC voltage [a.c. V]
Frequency [Hz]
Max. AC input current [a.c. A]
0.8 leading - 0.8 lagging
Power factor range
6000
6600
9200
6000
404027.4 32
7500 (PEA 6900)
7500 (PEA 7300)
7500
32.6 (PEA 33)
28.6
16
14.4
Max. Output Apparent Power [VA]
Rated Output Apparent Power [VA]
Max. recommended PV power [W]
Max. PV Voltage [d.c. V]
Nominal DC operating voltage [d.c. V]
MPPT voltage range [d.c. V]
MPPT full power voltage range [d.c. V]
Max. PV Current [d.c. A]
Isc PV array Short Circuit Current [d.c. A]
Start output voltage [d.c.V]
No. of MPP trackers
Strings per MPP tracker
4500
600
360
115-480
16/16
20/20
90
2
1
Model
X1-Hybrid-3.0 X1-Hybrid-3.7
5500
600
360
135-480
16/16
90
2
1
70-550
16/16
90
2
1
X1-Hybrid-6.0
360
225-480
16/16
90
2
1
X1-Hybrid-7.5
10000
600
280-480
20/20 20/20 20/20
Note: Marked with “" indicates that A single channel MPPT can only input a maximum of 5000W
16/16
90
2
1
20/20
5000 (Germany
4600, AU 4999)
5500 (Germany
4600, AU 4999)
23.9 (Germany
20, AU 21.7)
9200
5000
40
X1-Hybrid-5.0
X1-Hybrid-5.0
99.9%
97.0%
97.6%
97.0%
97.0%
1613
Rated Output Current [a.c. A]
21.7 26.1 32.6
X1-Hybrid-5.0
7500
600
360
190-480
X1-Hybrid-6.0
9000
600
360
(5.0K-D 4999)
(5.0K-D 4999)
X1-Hybrid-5.0K-D
Model
X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-6.0 X1-Hybrid-7.5
X1-Hybrid-5.0
X1-Hybrid-5.0K-D
X1-Hybrid-5.0K-D
X1-Hybrid-5.0K-D
Max. Output Continuous Current [a.c. A]
charge/discharge current [d.c. A]
Maximum output fault current (at 1ms)
Maximum output overcurrent
protection [a.c. A]
65
Max. inverter backfeed current to
the array [d.c.V]
0
0 0 0 0
Current (inrush)(at 5 0μs ) [ A]a. c .
91
10
Safety
IEC/EN 62109-1/-2
EN50549, VDE-AR-N 4105, C10/11, CEI 0-21, G98, G99, AS/NZS4777.2
Grid Monitoring
[a.c. A]