Technical Data
Technical Data
4.3 Battery (apply to version D/M)
4.4 Efficiency, Safety and Protection (apply to version D/M)
4 Technical Data
4.1 DC Input (apply to version D/M)
22
23
Integrated
Integrated
YES
YES
YES
YES
YES
Frequency Shift
YES
YES
YES
MPPT efficiency
European efficiency
Maximum efficiency
Model
X1-Hybrid-3.0 X1-Hybrid-3.7 X1-Hybrid-6.0
99.9%
97.0%
97.6%
97.0%
99.9%
97.0%
97.6%
97.0%
99.9%
97.0%
97.6%
97.0%
Max. battery charge efficiency
(PV to BAT) (@ full load)
Max. battery discharge efficiency
(BAT to AC) (@ full load)
97.0% 97.0% 97.0%
X1-Hybrid-7.5
99.9%
97.0%
97.6%
97.0%
97.0%
Security & Protection
DC SPD Protection
AC SPD Protection
Over/under voltage protection
Grid protection
DC injection monitoring
Back feed current monitoring
Residual current detection
Active anti-islanding method
Over load protection
Over heat protection
Array insulation resistance detection
Battery type
Battery voltage range [d.c. V]
Max. continuous
Communication interface
Reverse connection protection
Lithium batteries
80-480
30
CAN/RS485
Yes
Model
X1-Hybrid-3.0 X1-Hybrid-3.7 X1-Hybrid-6.0 X1-Hybrid-7.5
4.2
AC Output / Input (apply to version D/M)
Nominal AC voltage [a.c. V]
Frequency [Hz]
Power factor range
Total harmonic distortion (THDi)
3000
3300
3680
3680
AC Output
220/ 230/ 240 (180 to 270)
50/60
0.8 leading - 0.8 lagging
< 2%
AC Input
6300
3000
7360
3680
9200
220/230/240 (180 to 270)
50/60
Max. apparent power [VA]
Rated AC power [W]
Nominal AC voltage [a.c. V]
Frequency [Hz]
Max. AC input current [a.c. A]
0.8 leading - 0.8 lagging
Power factor range
6000
6600
9200
6000
404027.4 32
7500 (PEA 6900)
7500 (PEA 7300)
7500
32.6 (PEA 33)
28.6
16
14.4
Max. Output Apparent Power [VA]
Rated Output Apparent Power [VA]
Max. recommended PV power [W]
Max. PV Voltage [d.c. V]
Nominal DC operating voltage [d.c. V]
MPPT voltage range [d.c. V]
MPPT full power voltage range [d.c. V]
Max. PV Current [d.c. A]
Isc PV array Short Circuit Current [d.c. A]
Start output voltage [d.c.V]
No. of MPP trackers
Strings per MPP tracker
4500
600
360
115-480
16/16
20/20
90
2
1
Model
X1-Hybrid-3.0 X1-Hybrid-3.7
5500
600
360
135-480
16/16
90
2
1
70-550
16/16
90
2
1
X1-Hybrid-6.0
360
225-480
16/16
90
2
1
X1-Hybrid-7.5
10000
600
280-480
20/20 20/20 20/20
Note: Marked with " indicates that A single channel MPPT can only input a maximum of 5000W
16/16
90
2
1
20/20
5000 (Germany
4600, AU 4999)
5500 (Germany
4600, AU 4999)
23.9 (Germany
20, AU 21.7)
9200
5000
40
X1-Hybrid-5.0
X1-Hybrid-5.0
99.9%
97.0%
97.6%
97.0%
97.0%
1613
Rated Output Current [a.c. A]
21.7 26.1 32.6
X1-Hybrid-5.0
7500
600
360
190-480
X1-Hybrid-6.0
9000
600
360
(5.0K-D 4999)
(5.0K-D 4999)
X1-Hybrid-5.0K-D
Model
X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-6.0 X1-Hybrid-7.5
X1-Hybrid-5.0
X1-Hybrid-5.0K-D
X1-Hybrid-5.0K-D
X1-Hybrid-5.0K-D
Max. Output Continuous Current [a.c. A]
charge/discharge current [d.c. A]
Maximum output fault current (at 1ms)
Maximum output overcurrent
protection [a.c. A]
65
Max. inverter backfeed current to
the array [d.c.V]
0
0 0 0 0
Current (inrush)(at 5 0μs ) [ A]a. c .
91
10
Safety
IEC/EN 62109-1/-2
EN50549, VDE-AR-N 4105, C10/11, CEI 0-21, G98, G99, AS/NZS4777.2
Grid Monitoring
[a.c. A]

Other manuals for SolaX Power X1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X1 Series and is the answer not in the manual?

SolaX Power X1 Series Specifications

General IconGeneral
BrandSolaX Power
ModelX1 Series
CategoryInverter
LanguageEnglish

Related product manuals