5-40
DCR-TRV240/TRV340
3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT
1.
Initialization of 8, A, B, C, D, E, F, 1B, 1C, 1F Page Data
If the 8, A, B, C, D, E, F, 1B, 1C, 1F page data is erased due to some
reason, perform “1-2. INITIALIZATION OF PAGE DATA” of “5-
1. CAMERA SECTION ADJUSTMENT”
Note1: When reading or writing the 1B, 1C, 1D page data, select page: 0,
address: 10, and set data: 01, then select B, C or D page. The 1B.
1C or 1D page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: A page, B page and 1B page are DCR-TRV340 model only.
2. Serial No. Input
Note: Before performing the adjustments, check the data of page:
0, address: 10 is “00”. If not, set data: 00 to this address.
2-1. Company ID Input
Write the company ID in the EEPROM (nonvolatile memory).
Page 8
Address 8C, 8D, 8E, 8F, 90
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: 8, addresses: 8C to 90.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
3) Select page: 0, address: 01, and set data: 00.
2-2. Serial No. Input
Write the serial No. and model code in the EEPROM (nonvolatile
memory). Convert the serial No. on the name plate from decimal to
hexadecimal, and write in the EEPROM.
Page 8
Address 91, 92, 93
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. on the name plate, and take it as D1.
Example: If the serial No. is 77881.
D1=77881
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3) Obtain D2 and H1 corresponding to D1 from Table 5-3-2.
Example: If D1 is “77881”.
D2=D1–65536=12345
H1=FE
Table 5-3-2.
4) Input H1 to page: 8, address: 91. (Model code input)
Example: If H1 is “FE”.
Select page: 8, address: 91, set data: FE, and
press the PAUSE button.
5) Obtain the maximum decimal not exceeding D2 from Table 5-
3-3, and take this as D3.
Example: If D2 is “12345”.
D3 = 12288
6) Obtain the hexadecimal corresponding to D3 from Table 5-3-
3, and take this as H3.
Example: If D3 is “12288”.
H3 = 3000
7) Obtain the difference D4 between D2 and D3. (Decimal
calculation, 0 D4 255)
D4 = D2 – D3
Examp le: If D2 is “12345” and D3 is “12288”.
D4 = 12345 – 12288 = 57
8) Convert D4 to hexadecimal, and take this as H4.
(Refer to “Hexadecimal-decimal conversion table” in “5-4.
Service Mode”.)
Example: If D4 is “57”.
H4 = 39
9) Input the upper 2 digits of H3 to page: 8, address: 92.
Example: If H3 is “3000”.
Select page: 8, address: 92, set data: 30, and
press the PAUSE button.
10) Input H4 to page: 8, address: 93.
Example: If H4 is “39”.
Select page: 8, address: 93, set data: 39, and
press the PAUSE button.
11) Select page: 0, address: 01, and set data: 00.
Address
8C
8D
8E
8F
90
Data
08
00
46
01
02
D1 (Decimal)
000001 to 065535
065536 to 131071
131072 to 196607
D2 (Decimal)
D1
D1–65536
D1–131072
H
1
(Hexadecimal)
(Service model code)
FE
FE
FE