2 Product Description User Manual
10
25% Pn/min or
10% Pn/min
(1)
Disabled or 10% Pn/min
(2)
184.0 for stage I
103.5 for stage
II
195.5 for
stage I
34.5 for
stage II
3.0 for stage I
0.3 for stage II
1.5 for stage
I
0.2 for stage
II
(1) 25% Pn/min for initial connection and 10% Pn/min for reconnection.
(2) Disabled for initial connection and 10% Pn/min for reconnection.
(3) 30 s for initial connection and 300 s for reconnection.
Tab. 2-5 Multi-stage Voltage Protection Values for NL, EU, PL
195,5 for stage I, 115,0 for stage II
276,0 for stage I, 287,5 for stage II
10,0 for stage I, 0,1 for stage II
10,0 for stage I, 0,1 for stage II
Tab. 2-6 Default Values of Operational Voltage Parameters for FR
Disabled for initial connection and 10% Pn/min for reconnection.
Hereinafter, FR1, FR2 and FR3 stand for grids of France homeland
50 Hz, France overseas 50 Hz and France overseas 60 Hz
respectively. FR stands for all France region.
2.3.3 Regular Operational Frequency Range
The inverter can operate within the frequency allowable range for at least the