User Manual 4 Mechanical Mounting
29
IP65
4.2.1 Installation Environment Requirements
The installation environment is free of inflammable or explosive materials.
The location should be not accessible to children.
The ambient temperature and relative humidity must meet the following
requirements.
Max.
+60°C
Min.
-25°C
Max. RH
+100%
Prevent the inverter from direct exposure to sun, rain and snow.
The inverter should be well ventilated. Ensure air circulation.
Never install the inverter in living areas. The inverter will generate noise
during operation, affecting daily life.
4.2.2 Carrier Requirements
The installation carrier should meet the following requirements:
Made of non-inflammable materials
Max. load bearing capacity 4
times of inverter weight
KG
4.2.3 Installation Angle Requirements
Never install the inverter horizontally, or with a forward tilt or with a backward tilt
or even with upside down. The horizontal installation can result in damage to
the inverter.

Table of Contents

Other manuals for Sungrow SG2K5-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG2K5-S and is the answer not in the manual?

Sungrow SG2K5-S Specifications

General IconGeneral
BrandSungrow
ModelSG2K5-S
CategoryInverter
LanguageEnglish

Related product manuals