User Manual 10 Operation of LCD Display
75
Press to move the cursor and press
to change value. Press ENTER to
confirm setting.
The positive symbol “+” can be
changed to the negative symbol “-”.
The adjustment range is from -9999
to +9999 kWh.
(Energy-adj value)= (Real measured
value) - (E-tot reading value).
10.9.4 Load Default
All history information will be unrecoverable cleared and all parameters will
return to the default value except the protective parameters and time once
the “load default” operation is performed.
Main Screen (Press ENTER)Menu (Press ×3)Set-param(Press ENTER)Enter
password (Press ENTER)Sys-param(Press ENTER, Press ×3)Load default (Press
ENTER)
Press ENTER to confirm “load
default”.
10.9.5 Checking Firmware Version
Main Screen (Press ENTER)Menu (Press ×3)Set-param(Press ENTER)Enter
password (Press ENTER) Sys-param(Press ENTER, Press ×4) Firmware
version(Press ENTER)
Inverter shows detailed
firmware information, including
LCD version and DSP version.
The firmware version
information is read only.

Table of Contents

Other manuals for Sungrow SG50KTL-M-20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50KTL-M-20 and is the answer not in the manual?

Sungrow SG50KTL-M-20 Specifications

General IconGeneral
BrandSungrow
ModelSG50KTL-M-20
CategoryInverter
LanguageEnglish

Related product manuals