7-30 ELECTRICAL SYSTEM
BATTERY (DR-Z400E)
REMOVAL
Remove the battery cover. ( 6-2)
Remove the battery holder.
Remove the battery.
NOTE:
Disconnect the
-
battery lead wire, first.
SPECIFICATIONS
Type designation GT7B-4
Capacity 12 V, 23.4 kC (6.5 Ah)/10 HR
SERVICING
Visually inspect the surface of the battery container. If any signs
of cracking or electrolyte leakage from the sides of the battery
have occurred, replace the battery with a new one. If the battery
terminals are found to be coated with rust or an acidic white
powdery substance, clean the battery terminals with sandpa-
per.