5-8
MAINTENANCE
SERVICE DATA
REGULARLY REPLACE THE HYDRAULIC
OIL
When a hydraulic breaker is used, the oil
deteriorates more quickly than that used for
a usual excavation operation. Be sure to
replace the hydraulic oil and the return filter
elements.
• Failure to replace these in time can lead to
damage to the machine and the breaker
hydraulic system. To prolong the service life
of the hydraulic devices, properly replace
the hydraulic oil and the return filter
elements according to the table below.
• When replacing the hydraulic oil, clean the
suction strainer.
Replacement interval (hours)
Item Hydraulic oil
Filter element
1st time 25
2nd time 100
Periodically 1200 (600) 200
( ): When a conventional antiwear hydraulic
oil is used.
When the breaker operating ratio is 100%.
Refer to “Hydraulic breaker” on page 8-6.