CG-SVX17D-EN 9
Model Number Description
Unit Model Number
Digit 1-4 Chiller Model
CGAM Air-Cooled Scroll
Packaged Chiller
Digit 5-7 Unit Nominal Ton
020 20 Tons
026 26 Tons
030 30 Tons
035 35 Tons
040 40 Tons
052 52 Tons
060 60 Tons
070 70 Tons
080 80 Tons
090 90 Tons
100 100 Tons
110 110 To n s
120 120 Tons
130 130 Tons
Digit 8 Unit Voltage
A 208 Volt 60 Hz 3 Phase
B 230 Volt 60 Hz 3 Phase
D 380 Volt 60 Hz 3 Phase
E 400 Volt 50 Hz 3 Phase
F 460 Volt 60 Hz 3 Phase
G 575 Volt 60 Hz 3 Phase
Digit 9 Manufacturing
Plant
2 Pueblo, USA
Digit 10-11Design Seq
A-Z Factory/ABU Assigned
Digit 12 Unit Type
2 High Efficiency
Digit 13 Agency Listing
X No Agency Listing
A UL Listed to US and
Canadian Safety Standard
Digit 14 Pressure Vessel
Code
XNo Pressure Code
Digit 15 Unit Application
D Wide Ambient (0 to 125F/-
18 to 52C)
Digit 16 Refrigerant
Isolation Valves
2 Refrigerant Isolation
Valves (Discharge Valve)
Digit 17 Seismically Rated
A Not Seismically Rated Unit
B Seismically Rated Unit
Digit 18 Freeze Protection
(Factory-Installed Only)
1 With Freeze Protection
(External T-Stat Control)
Digit 19 Insulation
A Factory Insulation - All
Cold Parts
B Insulation for High
Humidity/Low Evap Temp
Digit 20 Factory Charge
1 Full Factory Refrigerant
Charge (HFC-410A)
2 Nitrogen Charge
Digit 21 Evaporator
Application
A Standard Cooling
(42 to 65°F/5.5 to 18°C)
B Low Temperature
Processing
(lower than 42°F/5.5°C)
C Ice-Making - hardwired
interface (20 to 65°F/-7 to
18°C)
Digit 22 Water Connection
1 Grooved Pipe Connection
Digit 23 Condenser Fin
Material
A Lanced Aluminum Fins
D Lanced Aluminum Fins w/
CompleteCoatâ„¢
Digit 24 Condenser Heat
Recovery
XNo Heat Recovery
1 Partial Heat Recovery w/
Fan Control
Digit 25 - Not Used
X
Digit 26 Starter Type
A Across the Line Starter/
Direct on Line
Digit 27 Incoming Power
Line Connection
1 Single Point Power
Connection
Digit 28 Power Line
Connection Type
A Terminal Block Conn. For
Incoming Lines
C Circuit Breaker
D Circuit Breaker with High
Fault Rated Control Panel
Digit 29 Enclosure Type
1 Water Tight (Per UL 1995
Standard)
Digit 30 Unit Operator
Interface
A Dyna-View/English
B Dyna-View/Spanish-Spain
C Dyna-View/Spanish-
Mexico
D Dyna-View/French
E Dyna-View/German
F Dyna-View/Dutch
G Dyna-View/Italian
H Dyna-View/Japanese
J Dyna-View/Portuguese-
Portugal
K Dyna-View/Portuguese-
Brazil
L Dyna-View/Korean
M Dyna-View/Thai
N Dyna-View/Simplified
Chinese
P Dyna-View/Traditional
Chinese
R Dyna-View/Russian
T Dyna-View/Polish
U Dyna-View/Czech
V Dyna-View/Hungarian
W Dyna-View/Greek
Y Dyna-View/Romanian
Z Dyna-View/Swedish
Digit 31 Remote Interface
(digital comm)
X No Remote Digital
Communication
2 LonTalk/Tracer Summit
Interface
3 Time of Day Scheduling
4 BACNet Interface
Digit 32 Ext. Chilled/Hot
Water and Curr. Demand
Limit Setpoint
X No Ext. Chilled Water
Setpoint
A Ext Chilled Water and
Demand Limit Setpoint - 4-
20mA
B Ext Chilled Water and
Demand Limit Setpoint - 2-
10Vdc
Digit 33 Percent Capacity
X Without % Capacity
1 With % Capacity
Digit 34 Programmable
Relays
X No Programmable Relays
A Programmable Relays
Digit 35 Pump Type
X No Pumps and no
Contactors
8 Dual High Head Pump
Digit 36 Pump Flow
Control
B Pump Flow Controlled by
Variable Speed Drive
Digit 37 Buffer Tank
XNo Tank
1With Tank