Phone Parameters - Administration Nur für den internen Gebrauch
A31003-S2000-R102-16-7620 02/2016
188 Provisioning Service, Developer’s Guide
c04.fm
Date and time
4.7 Date and time
WBM Name Item name Type Values Description
SNTP IP address sntp-addr IP ad-
dress or
host-
name.
Max. 64
charac-
ters.
Default: NULL IP address or hostname
of the SNTP server.
Timezone offset
(hours)
sntp-tz-
offset
Integer Default: 0 Shift in minutes in relation
to UTC. For HFA only rel-
evant if time source is
SNTP.
Daylight saving daylight-
save
Boolean true/false
Default: false,
OS40 US /
DPIP35 /
DPIP55: true
This item indicates
whether daylight saving is
required on the
phone.This is effectively
the master switch for the
feature, if it is set to false
then all daylight saving
Operation (auto or manu-
al ) is disabled. For HFA
only relevant if time
source is SNTP.
Difference (min-
utes)
daylight-
save-minutes
Integer 60 Time difference in relation
to regular time when day-
light saving time is in ef-
fect. For HFA only rele-
vant if time source is
SNTP.
Auto time change auto-
daylight-
save
Boolean true/false
Default: false,
OS40 US /
DPIP35 /
DPIP55: true
Enables or disables auto-
matic control of daylight
saving time according to
the DST (Daylight Saving
Time) zone selected. For
HFA only relevant if time
source is SNTP.