4.4. Control Box
4.4.1. Dismantling the Control Box
WARNING
Before replacing ANY components inside the Control Box, you MUST do a complete
shutdown.
Follow the first 3 steps in section Complete Rebooting Sequence
NOTICE
Exercise caution when handling ESD sensitive parts.
See section 2. Handling ESD-Sensitive Parts
If possible, lay the Control Box on its back.
Assembling is done in revers from the steps shown.
1. Power off Control Box follow step 1 to 3 in section Complete Rebooting Sequence
2. Remove all the I/O Terminals, the Fuse, SD-card and any other I/O etc. that may be
connected.
Service Manual 47 e-Series
Copyright © 2009–2024 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots UR e Series

Questions and Answers:

Universal Robots UR e Series Specifications

General IconGeneral
Payload3 kg, 5 kg, 10 kg, 16 kg
Power Supply100-240 VAC, 50-60 Hz
IP RatingIP54
Number of Axes6
Tool TCP Speed1 m/s
Degrees of Freedom6
Protection RatingIP54
ModelUR3e, UR5e, UR10e, UR16e
Reach500 mm, 850 mm, 1300 mm
Weight11.2 kg, 20.6 kg
Repeatability± 0.03 mm
Operating Temperature0 to 50 °C
Programming MethodTeach pendant (PolyScope), script, URCap
Communication InterfacesEthernet, Digital I/O
Safety StandardsEN ISO 10218-1, ISO/TS 15066