Components of the thermostat:
The illustration below shows the thermostat and its
components.
A
E
C
B
D
F
Item Description
A Uponor Smatrix Wave PLUS Thermostat D+RH T-167
B Wall bracket
C Stand
D Batteries (AAA 1.5 V)
E Mounting material
F Connection terminal
Uponor Smatrix Wave Thermostat Prog.+RH T-168
The thermostat shows the ambient, set temperature
or relative humidity, and time on the display. Settings
are adjusted using the +/- buttons on the front. Other
programmable settings are scheduling and individual
night set back (on a room by room basis) etc.
Main characteristics:
Backlit display, dims after 10 seconds of inactivity.
Displays Celsius or Fahrenheit.
Heating/cooling demand as well as low battery
indication in display.
Displays software version during power up
sequence.
Setup wizard to set time and date when installed for
the first time or after a factory reset.
Option to set the clock.
Setpoint range is 5 – 35 °C (maximum and
minimum setting may be limited by other system
settings).
Room temperature regulation with use of optional
external temperature sensors.
Displays optional temperature sensor values
if sensors are connected and relevant room
temperature regulation is activated.
Programmable to switch between Comfort and ECO
modes and adjustable ECO setback value. If an
external timer is available it can be used instead to
switch between Comfort and ECO.
Relative humidity limit indicated in display (requires
integration with a Wave/Wave PLUS/Space/Space
PLUS system).
Scheduling, pre-programmed and customizable
schedules.
Lower indoor temperature on a room by room basis
with night set back.
Can be placed up to 30 meters away from the
controller.
Components of the thermostat:
The illustration below shows the thermostat and its
components.
A
E
C
B
D
F
Item Description
A Uponor Smatrix Wave Thermostat Prog.+RH T-168
B Wall bracket
C Stand
D Batteries (AAA 1.5 V)
E Mounting material
F Connection terminal
Uponor Smatrix Wave Thermostat Public T-163
The thermostat is designed for public locations, which
means that the dial is hidden. It must be removed from
the wall to set the temperature. When it is removed, an
alarm is triggered.
Main characteristics:
Adjust setpoint temperature with a potentiometer
on the back of the thermostat.
Setpoint range is 5 – 35 °C (maximum and
minimum setting may be limited by other system
settings).
Optional external temperature sensor can be
connected to the thermostat.
DIP switch for selecting between function or sensor
mode of operation.
Enable or disable Comfort/ECO scheduling for the
zone with a DIP switch on the back.
Can be placed up to 30 meters away from the
controller.
UK
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
9
UPONOR SMATRIX MOVE/MOVE PLUS
·
INSTALLATION AND OPERATION MANUAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor SmatrixMove and is the answer not in the manual?

Uponor SmatrixMove Specifications

General IconGeneral
BrandUponor
ModelSmatrixMove
CategoryTemperature Controller
LanguageEnglish

Related product manuals